Higuchi Akio, Kubota Yoshihiro, Yokota Hajime, Miyazaki Hiroki, Ota Joji, Okafuji Yasuaki, Takaoka Hiroyuki, Uno Takashi
Аннотация
PURPOSE: Identification of the Adamkiewicz artery before aortic surgery is important for preventing postoperative complications due to spinal cord ischemia. The Adamkiewicz artery is difficult to identify due to its small diameter. Nitroglycerin has a vasodilatory effect and is used clinically to improve visualization of blood vessels on coronary computed tomography (CT) angiography. We investigated whether the vasodilatory effect of nitroglycerin could improve the ability to visualize the Adamkiewicz artery.
METHODS: We extracted 33 cases wherein contrast-enhanced CT images were taken before and after aortic aneurysm surgery. Nitroglycerin was administered for coronary artery evaluation on the preoperative CT. However, no nitroglycerin was administered before the postoperative CT. Aortic contrast-to-noise ratio, CT value, image noise, and diameter of the Adamkiewicz artery and anterior spinal artery were measured. The depiction of the Adamkiewicz artery was graded into four grades and evaluated. These measurements were performed by two independent reviewers.
RESULTS: In nitroglycerin-administered cases, the contrast-to-noise ratio and CT values were significantly higher (P < 0.001, P < 0.001, respectively); the Adamkiewicz artery and anterior spinal artery diameters were dilated (P = 0.005, P = 0.001, respectively). The Adamkiewicz artery score also improved significantly (P < 0.001). No significant difference was found in image noise.
CONCLUSION: Nitroglycerin contributed to improving the Adamkiewicz artery's visualization.
METHODS: We extracted 33 cases wherein contrast-enhanced CT images were taken before and after aortic aneurysm surgery. Nitroglycerin was administered for coronary artery evaluation on the preoperative CT. However, no nitroglycerin was administered before the postoperative CT. Aortic contrast-to-noise ratio, CT value, image noise, and diameter of the Adamkiewicz artery and anterior spinal artery were measured. The depiction of the Adamkiewicz artery was graded into four grades and evaluated. These measurements were performed by two independent reviewers.
RESULTS: In nitroglycerin-administered cases, the contrast-to-noise ratio and CT values were significantly higher (P < 0.001, P < 0.001, respectively); the Adamkiewicz artery and anterior spinal artery diameters were dilated (P = 0.005, P = 0.001, respectively). The Adamkiewicz artery score also improved significantly (P < 0.001). No significant difference was found in image noise.