Ultra-low-dose vs. standard-of-care-dose CT of the chest in patients with post-COVID-19 conditions-a prospective intra-patient multi-reader study.

Wassipaul Christian, Kifjak Daria, Milos Ruxandra-Iulia, Prayer Florian, Roehrich Sebastian, Winter Melanie, Beer Lucian, Watzenboeck Martin L, Pochepnia Svitlana, Weber Michael, Tamandl Dietmar, Homolka Peter, Birkfellner Wolfgang, Ringl Helmut, Prosch Helmut, Heidinger Benedikt H

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

To conduct an intrapatient comparison of ultra-low-dose computed tomography (ULDCT) and standard-of-care-dose CT (SDCT) of the chest in terms of the diagnostic accuracy of ULDCT and intrareader agreement in patients with post-COVID conditions.

METHODS

We prospectively included 153 consecutive patients with post-COVID-19 conditions. All participants received an SDCT and an additional ULDCT scan of the chest. SDCTs were performed with standard imaging parameters and ULDCTs at a fixed tube voltage of 100 kVp (with tin filtration), 50 ref. mAs (dose modulation active), and iterative reconstruction algorithm level 5 of 5. All CT scans were separately evaluated by four radiologists for the presence of lung changes and their consistency with post-COVID lung abnormalities. Radiation dose parameters and the sensitivity, specificity, and accuracy of ULDCT were calculated.

RESULTS

Of the 153 included patients (mean age 47.4 ± 15.3 years; 48.4% women), 45 (29.4%) showed post-COVID lung abnormalities. In those 45 patients, the most frequently detected CT patterns were ground-glass opacities (100.0%), reticulations (43.5%), and parenchymal bands (37.0%). The accuracy, sensitivity, and specificity of ULDCT compared to SDCT for the detection of post-COVID lung abnormalities were 92.6, 87.2, and 94.9%, respectively. The median total dose length product (DLP) of ULDCTs was less than one-tenth of the radiation dose of our SDCTs (12.6 mGy*cm [9.9; 15.5] vs. 132.1 mGy*cm [103.9; 160.2]; p < 0.001).

CONCLUSION

ULDCT of the chest offers high accuracy in the detection of post-COVID lung abnormalities compared to an SDCT scan at less than one-tenth the radiation dose, corresponding to only twice the dose of a standard chest radiograph in two views.

CLINICAL RELEVANCE STATEMENT: Ultra-low-dose CT of the chest may provide a favorable, radiation-saving alternative to standard-dose CT in the long-term follow-up of the large patient cohort of post-COVID-19 patients.

Для цитирования: Wassipaul Christian, Kifjak Daria, Milos Ruxandra-Iulia, Prayer Florian, Roehrich Sebastian, Winter Melanie, Beer Lucian, Watzenboeck Martin L, Pochepnia Svitlana, Weber Michael, Tamandl Dietmar, Homolka Peter, Birkfellner Wolfgang, Ringl Helmut, Prosch Helmut, Heidinger Benedikt H. Ultra-low-dose vs. standard-of-care-dose CT of the chest in patients with post-COVID-19 conditions-a prospective intra-patient multi-reader study.. European radiology. 2024. DOI: 10.1007/s00330-024-10754-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.