MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00431-023-05187-7

Медицинская библиотека · European journal of pediatrics · 2023

Electrocardiographic characteristics of newborns with ventricular septal defects: a Copenhagen Baby Heart Study.

Pihl Christian, Pærregaard Maria Munk, Sillesen Anne-Sophie, Vøgg Ruth Ottilia B, Pietersen Adrian, Raja Anna Axelsson, Iversen Kasper Karmark, Bundgaard Henning, Christensen Alex Hørby

СтатьяПеревод в очереди

Аннотация

Ventricular septal defects (VSD) represent the most common congenital heart defect in newborns. We assessed the electrocardiographic characteristics of newborns with VSDs in a general population sample. The Copenhagen Baby Heart Study is a prospective population-based cohort study offering cardiac evaluation of newborns. Echocardiograms and electrocardiograms were obtained within 30 days after birth and systematically analysed. A VSD was identified in 530 newborns (mean age 11 ± 7 days, 42% boys). Newborns with VSDs had a more left-shifted QRS axis (116 ± 34 vs. 120 ± 3°, p = 0.02), and a higher S-wave amplitude in V1 (721 ± 584 vs. 636 ± 549 µV, p = 0.001) than controls. The largest differences were found in newborns with large or perimembraneous VSDs with a higher frequency of left axis deviation, higher S-wave amplitudes in V1, and higher R- and S-wave amplitudes in V6 compared with controls. R-waves in V1 and V6 were significantly associated to left ventricular mass, whereas S-waves in V1 and V6 were dependent on left ventricular end-diastolic diameter on echocardiography.

Conclusion

Newborns with VSDs showed significant differences in QRS axis, and R- and S-wave precordial amplitudes compared to matched controls. Perimembranous and large VSDs had the greatest effect on the neonatal ECG. What is Known: • Ventricular septal defects in newborns are prevalent and may affect cardiac function and structure. What is New: • The Copenhagen Baby Heart Study is the largest study including a cohort of unselected newborns undergoing postnatal cardiac examination. • We found that newborns with VSD showed significant electrocardiographic differences depending on size and type of VSD compared with healthy newborns.

Для цитирования: Pihl Christian, Pærregaard Maria Munk, Sillesen Anne-Sophie, Vøgg Ruth Ottilia B, Pietersen Adrian, Raja Anna Axelsson, Iversen Kasper Karmark, Bundgaard Henning, Christensen Alex Hørby. Electrocardiographic characteristics of newborns with ventricular septal defects: a Copenhagen Baby Heart Study.. European journal of pediatrics. 2023. DOI: 10.1007/s00431-023-05187-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.