MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1210/jc.2006-0993

Медицинская библиотека · The Journal of clinical endocrinology and metabolism · 2006

Monitoring thyroglobulin in a sensitive immunoassay has comparable sensitivity to recombinant human tsh-stimulated thyroglobulin in follow-up of thyroid cancer patients.

Smallridge Robert C, Meek Shon E, Morgan Melissa A, Gates Geoffrey S, Fox Thomas P, Grebe Stefan, Fatourechi Vahab

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

CONTEXT: Most thyroglobulin (Tg) assays have a sensitivity of 0.5-1 ng/ml. A minority of patients with undetectable T4-suppressed Tg levels have a recombinant human TSH (rhTSH)-stimulated Tg above 2 ng/ml and identifiable residual disease.

OBJECTIVE

The objective was to determine whether a Tg assay with improved sensitivity could eliminate the need for rhTSH stimulation when baseline Tg is below 0.1 ng/ml.

DESIGN

A retrospective study of two academic endocrine practices was conducted.

POPULATION: A total of 194 patients undergoing rhTSH stimulation participated in the study.

RESULTS

Of the 80 patients with Tg below 0.1 ng/ml, two (2.5%) had rhTSH-stimulated Tg above 2 ng/ml. One other patient with stimulation to 0.3 ng/ml and negative 123I scan had an ultrasound-detected malignant lymph node resected. None had 131I/123I imaging after rhTSH stimulation suggestive of local recurrence or distant metastasis. If T4-suppressed Tg was 0.1-0.5 or 0.6-2.0 ng/ml, rhTSH Tg was above 2 ng/ml in 24.2 and 82.4%, respectively.

CONCLUSIONS

Patients with differentiated thyroid carcinoma and a T4-suppressed serum Tg below 0.1 ng/ml rarely have a rhTSH-stimulated Tg above 2 ng/ml, and none of these patients had 131I or 123I imaging after rhTSH stimulation suggestive of local recurrence or distant metastasis. We recommend monitoring such patients with a T4-suppressed Tg level and periodic neck ultrasonography. An increase in T4-suppressed serum Tg to a detectable level or the appearance of abnormal lymph nodes by physical or ultrasound exam should prompt further investigation.

Для цитирования: Smallridge Robert C, Meek Shon E, Morgan Melissa A, Gates Geoffrey S, Fox Thomas P, Grebe Stefan, Fatourechi Vahab. Monitoring thyroglobulin in a sensitive immunoassay has comparable sensitivity to recombinant human tsh-stimulated thyroglobulin in follow-up of thyroid cancer patients.. The Journal of clinical endocrinology and metabolism. 2006. DOI: 10.1210/jc.2006-0993.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.