INTRODUCTION

Tibial pilon fractures are often treated with initial external fixation followed by delayed definitive fixation. It has been postulated that the external fixator pin site may correlate with infection risk. The purpose of this study was to determine whether external fixator pin-site distance from definitive implants impacts the risk of deep infection in pilon fractures.

MATERIALS AND

METHODS

A retrospective cohort study was completed at a single level 1 trauma center. All patients ages 15-65 who underwent open reduction and internal fixation (ORIF) of a distal tibial fracture (AO/OTA Classification 43) from 2007 to 2013 were included. The final study population was 133 patients. The impact of external fixation pin location (relative to the definitive implant location) on postoperative infection was measured.

RESULTS

As a continuous variable, the distance between the closest pin site and plate was 62.1 ± 44.1 mm in the infected cohort and 62.2 ± 49.7 mm in the non-infected cohort (p = 0.991). Further analysis was performed by grouping the distances into less than 0 mm (i.e. overlapping), >0.0 - 25.0 mm, >25.0 - 50.0 mm, >50.0 - 75.0 mm, >75.0 - 100.0 mm, and >100.0 mm of separation. No significant differences were noted with regards to the risk for infection.

CONCLUSIONS

Staged care has been shown to be an effective treatment strategy for AO/OTA type 43 fractures. There are many variables to consider when placing an external fixator construct. In this cohort, pin site distance from definitive implant location was not associated with an increase in deep infections.

LEVEL OF EVIDENCE: Level III.

Для цитирования: Hadeed Michael M, Evans Cody L, Werner Brian C, Novicoff Wendy M, Weiss David B. Does external fixator pin site distance from definitive implant affect infection rate in pilon fractures?. Injury. 2018. DOI: 10.1016/j.injury.2018.10.041.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.