Range of Motion Following Extensor Tendon Splitting vs. Tendon Sparing Approaches for Plate Osteosynthesis of Proximal Phalangeal Fractures - A Systematic Review and Meta-Analysis.
Аннотация
Background
Several approaches to plate fixation of the proximal phalanx have been proposed, such as the dorsal extensor splitting approach and the lateral or dorso-lateral extensor sparing approach, which aims to minimise invasiveness to promote native extensor tendon glide. This study aimed to meta-analyse the outcomes of these two approaches.
Methods
A systematic review of electronic databases was undertaken, and the outcomes of comparative studies meta-analysed.
Results
Three studies were included for meta-analysis. Total active motion (TAM) was significantly greater in the extensor sparing group compared to the extensor splitting (Mean difference 8.52 degrees, 95%CI 0.8-16.36, p = 0.03).
Conclusions
This study demonstrates that there is preliminary evidence favouring the use of extensor sparing approaches when fixing proximal phalanxes - however, this result requires validation with randomised controlled trials.