MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/bf01254246

Медицинская библиотека · European journal of nuclear medicine · 1997

Comparison of fluorine-18 fluorodeoxyglucose positron emission tomography and technetium-99m methoxyisobutylisonitrile scintimammography in the detection of breast tumours.

Palmedo H, Bender H, Grünwald F, Mallmann P, Zamora P, Krebs D, Biersack H J

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

The aim of this study was to compare, in breast cancer patients, the diagnostic accuracy of positron emission tomography (PET) using fluorine-18 fluorodeoxyglucose (FDG) and scintimammography (SMM) using technetium-99m methoxyisobutylisonitrile (MIBI). A total of 20 patients (40 breasts with 22 lesions) were evaluated serially with MIBI and, on the following day, with FDG. For SMM, planar and single-photon emission tomography imaging in the prone position was performed starting at 10 min following the injection of MIBI (740 MBq). For PET, scans were acquired 45-60 min after the injection of FDG (370 MBq) and attentuation correction was performed following transmission scans. Results from SMM and PET were subsequently compared with the histopathology results. True-positive results were obtained in 12/13 primary breast cancers (mean diameter=29 mm, range 8-53 mm) with both FDG and MIBI. False-negative results were obtained in two local recurrences (diameter <9 mm) with both FDG and MIBI. In benign disease, FDG and MIBI did not localize three fibrocystic lesions, two fibroadenomas and one inflammatory lesion (true-negative), but both localized one fibroadenoma (false-positive). Collectively, the results demonstrate a sensitivity of 92%, and a specificity of 86%, for primary breast cancer regardless of whether FDG or MIBI was used. In contrast to MIBI scintigraphy, FDG PET scored the axillae correctly as either positive (metastatic disease) or negative (no axillary disease) in all 12 patients. The tumour/non-tumour ratio for MIBI was 1.97 (range 1.43-3.1). The mean standard uptake value (SUV) for FDG uptake was 2.57 (range 0.3-6.2). The diagnostic accuracy of SMM was equivalent to that of FDG PET for the detection of primary breast cancer. For the detection of in situ lymph node metastases of the axilla, FDG seems to be more sensitive than 99mTc-MIBI.

Для цитирования: Palmedo H, Bender H, Grünwald F, Mallmann P, Zamora P, Krebs D, Biersack H J. Comparison of fluorine-18 fluorodeoxyglucose positron emission tomography and technetium-99m methoxyisobutylisonitrile scintimammography in the detection of breast tumours.. European journal of nuclear medicine. 1997. DOI: 10.1007/bf01254246.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.