m+Medelevator.RU
← Поиск публикаций
Analytica chimica acta · 2023

Nile blue as reporter dye in salt aggregation based-colorimetric aptasensors for peptide, small molecule and metal ion detection.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Chovelon Benoît, Peyrin Eric, Ragot Mailys, Salem Nassim, Nguyen Truong Giang, Auvray Benjamin, Henry Mickael, Petrillo Mel-Alexandre, Fiore Emmanuelle, Bessy Quentin, Faure Patrice, Ravelet Corinne

Аннотация

Herein, we report a novel approach for the design of a colorimetric aptasensor, relying on a Dye Salt Aggregation-based Colorimetric Oligonucleotide assay (DYSACO assay). This method is based on the use of an intercalating agent, Nile Blue (NB), whose aggregation capacities (and thus modification of its absorption spectrum) are drastically amplified by adding salts to the working solution. The presence of an aptamer could protect NB from such aggregation process due to its intercalation into double-stranded DNA and/or interaction with nucleobases. In response to the addition of the specific ligand, the competition between NB and the target for binding to the aptamer occurs, resulting in an increase in the dye salt aggregation and then in the blue-to-blank color change of the solution. The proof-of-principle was demonstrated by employing the anti-l-tyrosinamide aptamer and the assay was successfully applied to the trace enantiomer detection, allowing the detection of an enantiomeric impurity down to approximately 2% in a non-racemic sample. Through a reversed mechanism based on the increased capture of NB by DNA upon analyte binding, the sensing platform was further demonstrated for the Hg(II) detection. Water samples of different origin were spiked with Hg(II) analyte at final range concentrations comprised between (0.5-15 μM). An excellent overall recovery of 122 ± 14%; 105 ± 14%; 99 ± 9%; was respectively obtained from river, tap and mineral water, suggesting that the sensor can be used under real sample conditions. The assay was also shown to work for sensing the ochratoxin A and d-arginine vasopressin compounds, revealing its simplicity and generalizability potentialities.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты