Non-invasive continuous cardiac output monitoring in infants with hypoxic ischaemic encephalopathy.

Garvey Aisling A, O'Neill Roisin, Livingstone Vicki, Pavel Andreea M, Finn Daragh, Boylan Geraldine B, Murray Deirdre M, Dempsey Eugene M

Наблюдательное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To describe early, continuous, non-invasive measures of cardiac output (CO) and evolution over time in infants with hypoxic-ischaemic encephalopathy (HIE).

STUDY

DESIGN

Prospective observational study of 44 infants with HIE (23 mild, 17 moderate, 4 severe) and 17 term controls. Infants with HIE had non-invasive CO monitoring (NICOM) continuously in the neonatal unit. Term controls had NICOM recorded at 6 and 24 h. A mixed-modelling approach was used to assess change in CO over time by group.

RESULTS

Infants with moderate HIE have significantly lower CO than the mild group at all timepoints (10.7 mls/kg/min lower, 95% CI:1.0,20.4, p = 0.03) which increases over time, driven by a gradual increase in stroke volume (SV). CO increased further during rewarming predominantly due to an increase in HR.

CONCLUSION

TH has a significant impact on HR but SV appears largely unaffected. NICOM may provide a non-invasive, continuous, low-cost alternative to monitoring CO in infants with HIE however further research is warranted.

Для цитирования: Garvey Aisling A, O'Neill Roisin, Livingstone Vicki, Pavel Andreea M, Finn Daragh, Boylan Geraldine B, Murray Deirdre M, Dempsey Eugene M. Non-invasive continuous cardiac output monitoring in infants with hypoxic ischaemic encephalopathy.. Journal of perinatology : official journal of the California Perinatal Association. 2022. DOI: 10.1038/s41372-022-01495-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.