MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/openhrt-2024-002937

Медицинская библиотека · Open heart · 2024

Predicting troponin biomarker elevation from electrocardiograms using a deep neural network.

Hilgendorf Lukas, Petursson Petur, Gupta Vibha, Ramunddal Truls, Andersson Erik, Lundgren Peter, Dworeck Christian, Ljungman Charlotta, Boren Jan, Rawshani Aidin, Omerovic Elmir, Smith Gustav, Mandalenakis Zacharias, Skoglund Kristofer, Rawshani Araz

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Elevated troponin levels are a sensitive biomarker for cardiac injury. The quick and reliable prediction of troponin elevation for patients with chest pain from readily available ECGs may pose a valuable time-saving diagnostic tool during decision-making concerning this patient population.

METHODS AND

RESULTS

The data used included 15 856 ECGs from patients presenting to the emergency rooms with chest pain or dyspnoea at two centres in Sweden from 2015 to June 2023. All patients had high-sensitivity troponin test results within 6 hours after 12-lead ECG. Both troponin I (TnI) and TnT were used, with biomarker-specific cut-offs and sex-specific cut-offs for TnI. On this dataset, a residual convolutional neural network (ResNet) was trained 10 times, each on a unique split of the data. The final model achieved an average area under the curve for the receiver operating characteristic curve of 0.7717 (95% CI±0.0052), calibration curve analysis revealed a mean slope of 1.243 (95% CI±0.075) and intercept of -0.073 (95% CI±0.034), indicating a good correlation between prediction and ground truth. Post-classification, tuned for F1 score, accuracy was 71.43% (95% CI±1.28), with an F1 score of 0.5642 (95% CI±0.0052) and a negative predictive value of 0.8660 (95% CI±0.0048), respectively. The ResNet displayed comparable or surpassing metrics to prior presented models.

CONCLUSION

The model exhibited clinically meaningful performance, notably its high negative predictive accuracy. Therefore, clinical use of comparable neural networks in first-line, quick-response triage of patients with chest pain or dyspnoea appears as a valuable option in future medical practice.

Для цитирования: Hilgendorf Lukas, Petursson Petur, Gupta Vibha, Ramunddal Truls, Andersson Erik, Lundgren Peter, Dworeck Christian, Ljungman Charlotta, Boren Jan, Rawshani Aidin, Omerovic Elmir, Smith Gustav, Mandalenakis Zacharias, Skoglund Kristofer, Rawshani Araz. Predicting troponin biomarker elevation from electrocardiograms using a deep neural network.. Open heart. 2024. DOI: 10.1136/openhrt-2024-002937.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.