MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2006.04.053

Медицинская библиотека · American journal of ophthalmology · 2006

Scanning laser polarimetry with variable corneal compensation and optical coherence tomography in tilted disk.

Yu Saiyuu, Tanabe Teruyo, Hangai Masanori, Morishita Shiho, Kurimoto Yasuo, Yoshimura Nagahisa

СтатьяПеревод в очереди

Аннотация

PURPOSE: To determine whether scanning laser polarimetry with variable corneal compensation (GDx-VCC) or optical coherence tomography (OCT) is helpful for the analysis of the retinal nerve fiber layer (RNFL) thickness in glaucoma subjects with tilted disk.

DESIGN

Retrospective case-control study.

METHODS

We included 21 glaucomatous eyes with tilted disk and 35 glaucomatous eyes without tilted disk. Peripapillary RNFL thickness measurement by GDx-VCC and OCT, and also visual field testing with a Humphrey Field Analyzer program 30-2 (HFA) were performed in all subjects.

RESULTS

In the group without tilted disk, the RNFL thickness values obtained with GDx-VCC and OCT analysis had a good correlation with mean deviation (MD), and clearly showed stage-dependent reduction. Conversely, in the group with tilted disk, a discrepancy in the RNFL measurement between GDx-VCC and OCT was observed. The correlation of RNFL measurement to the visual field was further examined at each hemifield (superior and inferior). In the group without tilted disk, the measurements of both instruments at each hemifield were in good correlation with the mean pattern deviation values. However, in the group with tilted disk, the GDx-VCC derived values did not correlate with the visual field defect in both hemifields, whereas OCT was in good association with both mean pattern deviation values. Infrared images acquired with a wavelength of nearly 780 nm revealed a high reflex from the sclera in the tilted disk.

CONCLUSIONS

Our study has suggested that RNFL analysis by OCT is more suitable for the glaucoma assessment in the tilted disk compared with GDx-VCC.

Для цитирования: Yu Saiyuu, Tanabe Teruyo, Hangai Masanori, Morishita Shiho, Kurimoto Yasuo, Yoshimura Nagahisa. Scanning laser polarimetry with variable corneal compensation and optical coherence tomography in tilted disk.. American journal of ophthalmology. 2006. DOI: 10.1016/j.ajo.2006.04.053.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.