Prospective comparative validation of a novel endoscopy chair and endoscope manipulation apparatus (EasyFlex) for ergonomic improvement in fURS procedures.

Toksoz Serdar, Asik Alper, Kizilkan Yalcin, Senel Samet, Koseoglu Burak, Erdogan Erhan, Sarica Kemal

СтатьяСравнительное исследованиеВалидационное исследованиеПеревод в очереди

Аннотация

BACKGROUND

This study aimed to validate the functionality and usability of a doctor's endoscopy chair and an endoscope carrying/manipulation apparatus known as the EasyFlex.

METHODS

Prototype models of the EasyFlex apparatus were evaluated by five expert urologists specializing in endourology at three medical centers. The surgical and ergonomic advantages of the doctor's endoscopy chair and the endoscope carrying/manipulation apparatus were compared with those used during traditional flexible ureterorenoscopy (fURS) procedures for kidney stones, with ergonomic outcomes assessed using the Ergomini scale.

RESULTS

The ergonomic evaluation of both systems revealed that surgeons experienced significantly greater ergonomic discomfort during traditional fURS procedures compared to those using the EasyFlex system, as indicated by higher total ergonomic scores (37.6 vs. 12.6, p < 0.001). Furthermore, the EasyFlex group demonstrated a significantly lower rate of intraoperative complications than the traditional fURS group (11.8% vs. 27%, p = 0.017).

CONCLUSION

Compared with the traditional approach, the results obtained in our study demonstrated that the EasyFlex apparatus could provide superior ergonomic conditions during fURS procedures. Additionally, the rate of intraoperative complications was lower in the EasyFlex group.

Для цитирования: Toksoz Serdar, Asik Alper, Kizilkan Yalcin, Senel Samet, Koseoglu Burak, Erdogan Erhan, Sarica Kemal. Prospective comparative validation of a novel endoscopy chair and endoscope manipulation apparatus (EasyFlex) for ergonomic improvement in fURS procedures.. BMC urology. 2026. DOI: 10.1186/s12894-026-02200-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.