DOI 10.1016/j.juro.2009.07.040
Interobserver agreement for noninvasive bladder pressure flow recording with penile cuff.
Аннотация
PURPOSE: We assessed variability in interpreting noninvasive measurements of bladder pressure and urine flow between experienced and novice users of the penile cuff.
MATERIALS AND
METHODS
Urodynamicists at 6 sites were asked to use the penile cuff test as part of clinical assessment in 30 men presenting with lower urinary tract symptoms. After a short training period they measured maximum flow rate and cuff interruption pressure from penile cuff test recordings to enable categorization of bladder outlet obstruction using a nomogram. Similar measurements were then made on the same traces by 2 expert observers from the originating center. Interobserver differences were assessed.
RESULTS
Complete agreement on obstruction categorization was seen in 77% of subjects, which increased to 86% when plots positioned on category boundary lines were allocated to the favored category. The 95% confidence limits of interobserver variability in maximum flow rate and cuff interruption pressure measurements were +/- 1.7 ml per second and +/- 13 cm H(2)O, respectively, although a small number of studies yielded discrepancies between observers that were larger than expected. They arose from complex recordings but were equally likely between experts as between expert and novice. Investigation of the causes suggested in some cases how such discrepancies may be avoided in the future.
CONCLUSIONS
The excellent level of agreement in measurement and categorization after a short training period suggests that introducing the penile cuff test as part of assessment in men with lower urinary tract symptoms would be straightforward.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.