DOI 10.1080/00016489.2025.2501598

Медицинская библиотека · Acta oto-laryngologica · 2025

Side selection of cochlear implant in patients after head trauma: a new perspective.

Zou Xinyue, Chen Jingyuan, Chen Biao, Shi Ying, Ma Chunling, Lu Simeng, Cheng Yujing, Kong Ying, Li Yongxin

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Head trauma often leads to bilateral sensorineural hearing loss (SNHL), and determining the optimal side for cochlear implantation (CI) remains a critical issue that requires further investigation.

Objective

To evaluate the role of preoperative aided threshold (AT) testing in selecting the optimal CI side for patients with bilateral SNHL caused by head trauma.

METHODS

This study included 9 patients with bilateral SNHL resulting from head trauma. Preoperative audiological and radiological evaluations were performed. The correlation between preoperative AT, duration of deafness (DoD), radiological findings, and Nijmegen Cochlear Implant Questionnaire (NCIQ) scores was analyzed.

RESULTS

Preoperative AT showed a tendency for a negative correlation with advanced sound perception scores (r = -0.740, p = 0.057), while DoD exhibited a significant negative correlation with auditory self-confidence (r = -0.803, p = 0.029). Imaging combined with AT provides a foundational framework for selecting the implantation side; however, the limited sample size restricts the generalizability of the findings.

CONCLUSION

Lower preoperative AT and shorter DoD may predict better auditory rehabilitation outcomes following CI. It is recommended to integrate imaging and audiological evaluations for individualized decision-making. Future studies with larger sample sizes are necessary to validate these findings and explore the clinical implications of early CI.

Для цитирования: Zou Xinyue, Chen Jingyuan, Chen Biao, Shi Ying, Ma Chunling, Lu Simeng, Cheng Yujing, Kong Ying, Li Yongxin. Side selection of cochlear implant in patients after head trauma: a new perspective.. Acta oto-laryngologica. 2025. DOI: 10.1080/00016489.2025.2501598.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.