Nuchal translucency and first trimester biochemical markers for down syndrome screening: a cost-effectiveness analysis.

Caughey Aaron B, Kuppermann Miriam, Norton Mary E, Washington A Eugene

Сравнительное исследованиеСтатьяПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

OBJECTIVE

The purpose of this study was to perform a cost-effectiveness analysis that compared the first- and second- trimester screening tools for Down syndrome.

STUDY

DESIGN

A decision tree was designed that compared four possible screens for Down syndrome: (1) current second- trimester expanded maternal serum alpha-fetoprotein test (AFP), (2) first-trimester nuchal translucency screen, (3) first-trimester serum screen, and (4) combined first-trimester screen with both nuchal translucency screen and a serum screen. Incremental cost-benefit and cost-effectiveness ratios were calculated that compared the first-trimester screens with expanded alpha-fetoprotein.

RESULTS

The combined screen (nuchal translucency screen + first-trimester serum screen) identified 3,833 Down syndrome fetuses, the nuchal translucency alone identified 3,413 Down syndrome fetuses, and the first- trimester serum screen identified 2,993 Down syndrome fetuses. Each of these screens was an improvement over the current expanded AFP screen, which diagnosed 2,446 Down syndrome fetuses. It would cost $98,381 for each additional Down syndrome case that would be identified by nuchal translucency alone, with a benefit-to-cost ratio of 4.85. The addition of the first-trimester serum screen is still cost-effective compared with expanded AFP; the cost would be $319,934 for each additional Down syndrome fetus who was identified, which would be a benefit-to-cost ratio of 1.57.

CONCLUSION

First-trimester screening for Down syndrome with nuchal translucency screening alone or with serum markers is more clinically effective and cost-effective than the current expanded AFP screen that is being used.

Для цитирования: Caughey Aaron B, Kuppermann Miriam, Norton Mary E, Washington A Eugene. Nuchal translucency and first trimester biochemical markers for down syndrome screening: a cost-effectiveness analysis.. American journal of obstetrics and gynecology. 2002. DOI: 10.1067/mob.2002.127144.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.