MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bioadv.2025.214655

Медицинская библиотека · Biomaterials advances · 2025

Semi-degradable biomimetic double-layer small diameter vascular graft for arteriovenous fistula in large animals.

Fang Zhiping, Xiao Yonghao, Li Jubo, Li Hailei, Wu Xin, Ye Lin, Feng Zenggguo

СтатьяПеревод в очереди

Аннотация

A double layer small diameter vascular graft (SDVG) was fabricated by sequential electrospinning. The inner layer was composed by three kinds of biodegradable poly (ε-caprolactone) (PCL) fibers with three different molecular weights to induce endothelial regeneration and the outer layer comprised non-degradable thermoplastic polyurethane (TPU) fibers and PCL fibers with the numerical molecular weight of 80,000 g/mol to provide long-term mechanical support. The SDVG was further heparinized through "erosion and graft" strategy. The surface heparin content, the clotting time and the mechanical properties were evaluated in vitro. Then, the double layer SDVG was implanted into the sheep for six months as the arteriovenous fistula connecting carotid artery and jugular vein. The Doppler ultrasonic measurement and angiography showed the patency of the transplanted SDVGs and the in situ puncture test exhibited the potential of the SDVG for hemodialysis. H&E and Masson staining characterized the remodeling of the inner layer, whereas Safranin O and von Kossa staining demonstrated the regeneration of extracellular matrix and the absence of the calcification in the implanted SDVG. More importantly, the perfect regeneration of endothelium on the lumen of the SDVG was proven by CD31 staining. Consequently, the as-prepared SDVG showed the potential to be the artificial arteriovenous fistula in the clinic.

Для цитирования: Fang Zhiping, Xiao Yonghao, Li Jubo, Li Hailei, Wu Xin, Ye Lin, Feng Zenggguo. Semi-degradable biomimetic double-layer small diameter vascular graft for arteriovenous fistula in large animals.. Biomaterials advances. 2025. DOI: 10.1016/j.bioadv.2025.214655.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.