Ultra-high resolution Photon-Counting CTA for follow-up assessment of intracranial aneurysms after flow diverter: Initial experience.

Li Ruixi, He Naying, Cui Ying, Lyu Haiying, Xu Zhihan, Haller Sven, Zhu Chengcheng, Chang Rui, Dong Haipeng, Han Wentao, Deng Rong, Haacke Ewart Mark, Yan Fuhua, Jiang Hong

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Accurate imaging follow-up after flow diverter (FD) treatment is essential, but digital subtraction angiography (DSA) is invasive and conventional CT lacks resolution. Photon-counting CT angiography (PCCTA) offers ultra-high resolution (UHR) and improved artifact reduction. This study compared UHR-PCCTA versus standard resolution (SR)-PCCTA and DSA for comprehensive post-FD assessment.

METHODS

This prospective study consecutively enrolled 47 participants treated with FD and subsequently underwent PCCTA with UHR and SR reconstructions between August 2023 and August 2024. Two readers independently analyzed images blindly, including aneurysm size, occlusion status, neck coverage, wall apposition, stent deformation, branch vessel with Likert-scale (1-5). Inter-rater reliability for both UHR and SR-PCCTA was assessed using the intraclass correlation coefficient (ICC) and weighted Cohen's kappa. Diagnostic performance of PCCTA within 1 month after FD was compared with that of immediate post-deployment DSA using confusion matrix.

RESULTS

Totally 47 participants with 57 intracranial aneurysms treated with 51 FD stents. UHR-PCCTA exhibited higher diagnostic confidence (median = 5, IQRs = 5-5) compared to SR-PCCTA (median = 4, IQRs = 4-5, P < 0.05). UHR-PCCTA demonstrated a trend toward higher inter-rater agreement (κ: 0.814-1.0; ICC :0.902-0.960) relative to SR-PCCTA (κ: 0.668-1.0; ICC: 0.873-0.966) among both aneurysm and stent morphology. Compared with immediate post-deployment DSA, UHR-PCCTA showed excellent diagnostic accuracy for aneurysm neck coverage (93.3%), wall apposition (100.0%), stent deformation (93.8%), branch vessel inclusion (93.3%), along with very-good accuracy for aneurysm occlusion (88.2%).

CONCLUSION

UHR-PCCTA demonstrates high reliability and diagnostic accuracy in the assessment of intracranial aneurysms following FD treatment. Its comprehensive imaging evaluation capability has the potential to inform clinical decision-making.

Для цитирования: Li Ruixi, He Naying, Cui Ying, Lyu Haiying, Xu Zhihan, Haller Sven, Zhu Chengcheng, Chang Rui, Dong Haipeng, Han Wentao, Deng Rong, Haacke Ewart Mark, Yan Fuhua, Jiang Hong. Ultra-high resolution Photon-Counting CTA for follow-up assessment of intracranial aneurysms after flow diverter: Initial experience.. European journal of radiology. 2026. DOI: 10.1016/j.ejrad.2026.112893.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.