MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00347-014-3097-x

Медицинская библиотека · Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft · 2015

[Original preparations versus generics--latanoprost: how similar is different?].

Leitritz M A, Lipp H-P, Voykov B, Ziemssen F

СтатьяПеревод в очереди

Аннотация

BACKGROUND

To test the interchangeability of the commercially available (in Germany) latanoprost drugs and their generics respectively, the concentration of the active substance was tested. Guidelines of the European Medicines Agency postulate a sufficient bioequivalence, if the range of the agent is within 80-125% of the original drug.

METHODS

All compounds of latanoprost were procured registered. The concentration of latanoprost and benzalkoniumchloride was measured by high-performance liquid chromatography (HPLC) in a validated reference labroratory for 23 generics. In addition, the mean volume of drops and the pH of the formulation were measured. The packaging label and the readability of the enclosed information leaflet were checked.

RESULTS

All products contained less than 50 μg/ml latanoprost. The deviating reduction of the active substance (mean: - 7.39%, ± 2.8%) was accompanied by fluctions of the eyedrops' mass (mean: 0.03 g, ± 0.002 g). The concentration of benzalkonium chloride was mostly increased (median: 5.45%, min: - 2.5%, max: 11.5%). The pH of the original drug and the generics (median 6.78, min: 6.62, max: 6.81) was similar to the original drug, but was significantly different from an unpreserved formulation (pH 7.18). Due to type size, the packaging leaflet was illegible for humans with impaired vision.

CONCLUSIONS

Before prescribing generics in ophthalmology, different factors have to be considered, which might influence the amount of IOP lowering in effect. In the absence of healthcare research it is still unclear, how different bottle forms of eyedrops--such as appearance (e.g. Cyrillic characters) or pressure point (administration)--reduce the adherence of glaucoma patients.

Для цитирования: Leitritz M A, Lipp H-P, Voykov B, Ziemssen F. [Original preparations versus generics--latanoprost: how similar is different?].. Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft. 2015. DOI: 10.1007/s00347-014-3097-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.