MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2026.03.1896

Медицинская библиотека · Heart rhythm · 2026

Safety and effectiveness of zero-fluoroscopy atrial fibrillation ablation in community hospitals vs tertiary centers.

Navarrete Antonio J, Lambert Nate, Fisch Mark, Hajj Makram, Rios-Meza Hugo, Colter Shannon, Bharath Raju, Whipp Aaron, Iqtidar Faroq, Phookan Sujoy, Mitilesh Das, Miller John

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

Catheter ablation of atrial fibrillation (AF) is primarily performed at tertiary hospitals (THs). The safety and effectiveness of AF ablation at community hospitals (CHs) remains unclear.

OBJECTIVE

This study aimed to assess the long-term efficacy and safety of paroxysmal AF (PAF) ablation at CHs.

METHODS

We retrospectively analyzed patients evaluated at 2 CHs who underwent zero-fluoroscopy (ZF) pulmonary vein isolation at a TH (2015-2017) with those ablated at CHs (2017-2021) after implementation of a local ablation program. Patients were followed up for 24 months (m) with event monitors and self-wearable cardiac monitoring devices. Propensity score matching (PSM) yielded 2 matched cohorts of 290 patients (mean age 66 ± 5 years; 70% male; CHA2DS2-VASc score 1 ± 2; ejection fraction 55%).

RESULTS

No intraprocedural complications or transfers occurred. CH patients had lower AF recurrence at 12 and 18 m (17% vs 29%, P = .010; 23% vs 42%, P = .05), shorter diagnosis-to-ablation time (DAB) (6.1 ± 1.2 m vs 12.4 ± 2.5 m, P = .01), and higher same-day discharge rates (93% vs 70%, P = .010). AF recurrence was similar at 24 m (20%), but repeat ablation was higher in TH patients (27% vs 7%, P = .01). Longer DAB predicted AF recurrence at 18 m (hazard ratio [HR], 2.63; 95% confidence interval [CI], 1.65-4.21), with greater risk for DAB = 6-9 m (HR, 3.13; 95% CI, 2.136-3.13) and DAB >9 m (HR, 3.7; 95% CI, 2.30-3.75) compared with <3 m.

CONCLUSION

Ablation of PAF at CHs with ZF is safe with a shorter DAB and decrease AF recurrences when compared with TH.

Для цитирования: Navarrete Antonio J, Lambert Nate, Fisch Mark, Hajj Makram, Rios-Meza Hugo, Colter Shannon, Bharath Raju, Whipp Aaron, Iqtidar Faroq, Phookan Sujoy, Mitilesh Das, Miller John. Safety and effectiveness of zero-fluoroscopy atrial fibrillation ablation in community hospitals vs tertiary centers.. Heart rhythm. 2026. DOI: 10.1016/j.hrthm.2026.03.1896.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.