MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.lanplh.2025.101317

Медицинская библиотека · The Lancet. Planetary health · 2025

Sustainable cooling strategies for workers in the ready-made garment factory industry in Bangladesh under simulated extreme heat: a randomised crossover trial.

Smallcombe James W, Ranhotty Ruindu N, Bach Aaron J E, Palutikof Jean P, Tonmoy Fahim N, Joarder Ashikur R, Hossain Monir, Morris Nathan B, Capon Anthony, Mavros Yorgi, Jay Ollie

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Bangladesh frequently experiences extreme heat and humidity, which threatens the health, wellbeing, and productivity of ready-made garment workers. Scalable, sustainable, and low-cost cooling strategies are urgently needed to protect this workforce in low-income and middle-income countries. Therefore, we examined the effects of building-level and personal-level cooling alternatives to air conditioning on worker heat strain in a simulated Bangladesh ready-made garment factory.

METHODS

In a randomised cross over trial (ACTRN12622000457741), healthy participants (aged 18-40 years) recruited from a convenience sample of volunteers from diverse ethnic backgrounds completed six 3-h gender-specific ready-made garment work simulations (males ironed and females sewed) in a climate chamber at the University of Sydney: (1) current factory (control [CON]=40°C, 38% relative humidity); (2) CON with fan (FAN); (3) FAN with drinking water (FAN+HYD); (4) modified rooftop (ROOF=37·5°C, 38% relative humidity); (5) ROOF with fan (ROOF+FAN); and (6) air conditioning (AC=24°C, 40% relative humidity). Primary outcomes were end-trial core temperature, heart rate, and sweat loss fluid deficit. Linear mixed models with fixed effects of intervention and sex and random effects of participant were used for analysis. Pre-planned contrasts compared each intervention to CON, with Dunnett's correction for multiple testing.

FINDINGS: Between March 16, 2022, and Nov 25, 2023, 42 participants (20 identifying as females, 22 as males) completed 247 trials. Compared to CON, male core temperature decreased with FAN+HYD (-0·27°C [99% CI -0·44 to -0·09]), ROOF (-0·35°C [-0·53 to -0·17]), ROOF+FAN (-0·28°C [-0·45 to -0·10]), and AC (-0·71°C [-0·89 to -0·53]), but in females, core temperature decreased only with AC (-0·42°C [-0·60 to -0·24]). Male heart rate was lower with FAN (-6 beats per minute [-12 to 0]), FAN+HYD (-13 beats per minute [-19 to -7]), ROOF (-8 beats per minute [-14 to -2]), ROOF+FAN (-11 beats per minute [-17 to -5]), and AC (-34 beats per minute [-41 to -28]), and female heart rate was lower with FAN+HYD (-7 beats per minute [-13 to 0]), ROOF (-8 beats per minute [-15 to -2]), ROOF+FAN (-10 beats per minute [-16 to -4]), and AC (-25 beats per minute [-31 to -18]). Male sweat loss fluid deficit was reduced with FAN+HYD (-704 g [-817 to -591]), ROOF (-205 g [-317 to -93]), and AC (-853 g [-966 to -741]), and in females with FAN+HYD (-439 g [-554 to -324]), ROOF (-131g [-246 to -16]), and AC (-513g [-628 to -398]).

INTERPRETATION: Sustainable cooling interventions can reduce physiological heat strain under peak heat stress conditions in a typical non-airconditioned Bangladeshi ready-made garment factory. Cooling benefits were greater in males, highlighting potential gender-based workplace heat stress inequalities.

FUNDING: Wellcome Trust.

Для цитирования: Smallcombe James W, Ranhotty Ruindu N, Bach Aaron J E, Palutikof Jean P, Tonmoy Fahim N, Joarder Ashikur R, Hossain Monir, Morris Nathan B, Capon Anthony, Mavros Yorgi, Jay Ollie. Sustainable cooling strategies for workers in the ready-made garment factory industry in Bangladesh under simulated extreme heat: a randomised crossover trial.. The Lancet. Planetary health. 2025. DOI: 10.1016/j.lanplh.2025.101317.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.