MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jbmb.70036

Медицинская библиотека · Journal of biomedical materials research. Part B, Applied biomaterials · 2026

PEGylated Gold Nanoparticles as Novel Agglutination Enhancement Medium for Antibody Screening Test.

Noordin Siti Salmah, Ishak Nordiyana, Zabidi Muhammad Azrul, Hamid Zuratul Ain Abdul, Mohammed Rafeezul, Aziz Mohd Yusmaidie

СтатьяПеревод в очереди

Аннотация

To develop a novel enhancement medium using polyethylene glycol (PEG)-conjugated gold nanoparticles (AuNPs) for improved detection of clinically significant alloantibodies in antibody screening tests (AST), addressing the limitations of low ionic strength solution (LISS). PEG AuNPs were synthesized through a one-step method and characterized using UV-Visible spectroscopy, EFTEM, FESEM, particle size analysis, zeta potential measurement, and FT-IR spectroscopy. The PEG AuNPs' performance was evaluated against LISS in 120 plasma samples (both antibody-positive and negative) by scoring RBC agglutination reactions. Synthesized PEG AuNPs showed a ruby red color with a single absorption peak at 529 nm, confirming AuNP surface plasmon resonance. Spherical colloids averaged 152.73 ± 19.59 nm, with stability indicated by a zeta potential of -6.24 ± 0.57 mV. Significantly higher RBC agglutination scores were observed with PEG AuNPs during the anti-human globulin (AHG) phase (p = 0.010), especially for anti-D and anti-Lea/anti-Leb antibodies (p = 0.007 and 0.036, respectively). PEGylated AuNPs significantly enhanced RBC agglutination reactions compared to LISS, particularly for anti-D and combined anti-Lea/anti-Leb antibodies, presenting a promising alternative for AST.

Для цитирования: Noordin Siti Salmah, Ishak Nordiyana, Zabidi Muhammad Azrul, Hamid Zuratul Ain Abdul, Mohammed Rafeezul, Aziz Mohd Yusmaidie. PEGylated Gold Nanoparticles as Novel Agglutination Enhancement Medium for Antibody Screening Test.. Journal of biomedical materials research. Part B, Applied biomaterials. 2026. DOI: 10.1002/jbmb.70036.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.