DOI 10.1007/s10396-020-01056-0
Reliability of shoulder muscle stiffness measurement using strain ultrasound elastography and an acoustic coupler.
Аннотация
PURPOSE: Abnormal increases in muscle tone can be caused by various musculoskeletal disorders. The objective of this study was to evaluate intratester and intertester reliabilities in measuring the stiffness of the shoulder muscles using strain ultrasound elastography (USE) and an acoustic coupler.
METHOD: Tissue stiffness was measured in the trapezius muscle and in the supraspinatus muscle of healthy young volunteers.
RESULTS
The mean strain ratios measured by two experienced shoulder surgeons were significantly higher in the trapezius muscle than in the supraspinatus muscle (P < 0.001). Intratester reliability was rated as moderate to substantial for the trapezius muscle and substantial for the supraspinatus muscle. Intertester reliability was substantial for both muscles, with an intraclass correlation coefficient (2,1) of 0.62 [95% confidence interval (CI) 0.28-0.82] for the trapezius muscle and 0.69 (95% CI 0.40-0.86) for the supraspinatus muscle.
CONCLUSIONS
We found substantial intratester and intertester reliabilities for the trapezius and supraspinatus muscles, suggesting that USE represents a promising modality for measuring the stiffness of shoulder muscles. However, the clinical application of this method will require the development of a device that can standardize the scanning technique to further increase the reliability.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.