MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jcu.22565

Медицинская библиотека · Journal of clinical ultrasound : JCU · 2017

Terlipressin-induced modifications of Doppler ultrasound signals of systemic arteries in preterm infants with vasoactive-resistant patent ductus arteriosus: A pilot study.

Radicioni M, Bini V, Campus G M, Camerini P G

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

PURPOSE: To study the effects of terlipressin (TP) infusion on systemic perfusion, estimated with pulsed-wave Doppler ultrasonography of systemic arteries, in a population of extremely low birth-weight (ELBW) preterm infants with vasoactive-resistant ductus arteriosus.

METHODS

This prospective, observational cohort included, during five years, 12 ELBW infants with hemodynamically significant patent ductus arteriosus and absent or reversed diastolic flow at Doppler ultrasonography of systemic arteries, despite treatment and high-dose vasoactive support. We measured flow velocity of the anterior cerebral, right renal, and superior mesenteric arteries before and after TP infusion. Changes were evaluated by Spearman's rho coefficient analysis, Wilcoxon signed-rank, and Friedman test.

RESULTS

Time-averaged mean velocity of the renal artery (P = .028) increased, while renal pulsatility (P = .010) and resistance (P = .004) indexes, and cerebral artery resistance index (P = .021) decreased after TP infusion. Time-averaged mean velocity of the anterior cerebral artery proportionately increased with dopamine dose (rho = 0.678; P = .015), but showed opposite shifts after TP (rho = -0.662; P = .024).

CONCLUSIONS

These changes suggest that TP may improve systemic perfusion in the ELBW infants with vasoactive-resistant ductus arteriosus.

Для цитирования: Radicioni M, Bini V, Campus G M, Camerini P G. Terlipressin-induced modifications of Doppler ultrasound signals of systemic arteries in preterm infants with vasoactive-resistant patent ductus arteriosus: A pilot study.. Journal of clinical ultrasound : JCU. 2017. DOI: 10.1002/jcu.22565.