MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jpedsurg.2013.03.015

Медицинская библиотека · Journal of pediatric surgery · 2013

Collaboration in simulation: the development and initial validation of a novel thoracoscopic neonatal simulator.

Barsness Katherine A, Rooney Deborah M, Davis Lauren M

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

PURPOSE: We sought to create and validate a high fidelity, anatomically correct real tissue simulation model for thoracoscopic esophageal atresia/tracheoesophageal fistula (EA/TEF) repair.

METHODS

A scale reproduction of a neonatal rib cage was created. Surgically modified (EA/TEF) fetal bovine tissue completed the simulator. Nine pediatric surgery fellows and two attending pediatric surgeons (n=11) performed the simulated thoracoscopic EA/TEF repair. Participants completed a self-report rating scale, ranging from 1 (Don't know) to 5 (Highly realistic). Construct validity relevant to test content was evaluated by examining the ratings using the many-Facet Rasch model.

RESULTS

Analyses indicated no differences when comparing faculty (Observed Average (OA)=4.5/5.0) to fellow (OA=3.3) ratings, p=.71. In descending order, observed averages of the domains were 4.7 (Relevance), 4.5 (Physical attributes), 4.5 (Realism of materials), 4.4 (Ability to perform task), and 4.2 (Value). The observed Global opinion rating indicated the simulator can be considered for teaching thoracoscopic EA/TEF repair but could be improved slightly.

CONCLUSIONS

Fellow and faculty ratings indicated the simulator was valuable as a learning tool with minor modifications. Comments were consistent with high physical attribute ratings.

Для цитирования: Barsness Katherine A, Rooney Deborah M, Davis Lauren M. Collaboration in simulation: the development and initial validation of a novel thoracoscopic neonatal simulator.. Journal of pediatric surgery. 2013. DOI: 10.1016/j.jpedsurg.2013.03.015.