MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acsnano.5c13773

Медицинская библиотека · ACS nano · 2025

An Ultralong-Circulating Tantalum-Based Computed Tomography Contrast Agent for Vascular Imaging in Large Animals.

Shu Gang, Lang Mingbin, Deng Jianqi, Zhang Yuping, Cheng Ran, Pan Jinbin, Wang Xiaoyi, Liu Dingbin, Zhang Cai, Chen Xiaoyuan, Sun Shao-Kai

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Computed tomography angiography (CTA) is a critical tool for the diagnosis and prognostic evaluation of vascular diseases in clinical practice, but current CT contrast agents fall short of meeting the demands for real-time, long-term, and high-resolution imaging. This study presents an ultra-long-term CTA method enabled by PEGylated ultrasmall tantalum oxide nanoparticles (Ta2O5-PEG NPs) for accurate imaging evaluation of cardiovascular diseases based on the blood clearance mechanism of NPs. This contrast agent featured exceptional water solubility (800 mg mL-1), strong X-ray attenuation, good biocompatibility, and large-scale production ability. With a compact hydrodynamic diameter (∼10 nm) and nearly neutral surface charge, Ta2O5-PEG NPs exhibited prolonged blood circulation (half-lives of 19.84 h in rats and 18.23 h in rabbits) and an extended imaging window of up to 10 h post-injection. Comparative studies in rat, rabbit, and preclinical porcine models demonstrated that Ta2O5-PEG NPs enabled high-resolution, whole-body vascular visualization, and supported accurate diagnosis and postoperative evaluation of vascular stenosis and thrombosis from single administration. The proposed ultra-long-term CTA strategy, leveraging non-iodinated high atomic number elements, offers a precise imaging approach with clinical translation potential for the pre- and post-treatment evaluation of vascular diseases.

Для цитирования: Shu Gang, Lang Mingbin, Deng Jianqi, Zhang Yuping, Cheng Ran, Pan Jinbin, Wang Xiaoyi, Liu Dingbin, Zhang Cai, Chen Xiaoyuan, Sun Shao-Kai. An Ultralong-Circulating Tantalum-Based Computed Tomography Contrast Agent for Vascular Imaging in Large Animals.. ACS nano. 2025. DOI: 10.1021/acsnano.5c13773.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление