MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/0028-3886.314585

Медицинская библиотека · Neurology India · 2021

Robot-guided Ventriculoperitoneal Shunt in Slit-like Ventricles.

Doddamani Ramesh S, Meena Rajesh, Sawarkar Dattaraj, Singh Pankaj, Agrawal Deepak, Singh Manmohan, Chandra Poodipedi S

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Ventriculoperitoneal shunt (VPS) is the most common procedure used in the management of hydrocephalus regardless of the etiology. The standard free-hand technique is used for the placement of VPS in patients with enlarged ventricles. In patients with very small ventricles, CSF access through ventriculostomy becomes challenging and free-hand technique may be associated with high failure rates. In these situations, stereotactic-guided VPS becomes very useful.

OBJECTIVE

To validate and describe the technique of robotic-guided VPS in cases with very small ventricles.

METHODS

Three patients underwent VPS with robotic guidance between 2016 and 2019. One patient with a diagnosis of occipital meningocele, who later developed recalcitrant CSF leak from the operative site, and two other patients were diagnosed with idiopathic intracranial hypertension (IIH). Plain CT brain with 1-mm slice thickness acquired prior to the surgery was uploaded into the ROSA machine (Zimmer Biomet Warsaw, Indiana). The trajectory for the VPS is created on the robotic software presurgery. The patient is placed in the supine position with head turned to the side contralateral to VPS insertion and fixed with Mayfield clamp. Registration of the patient is done with the robot. The placement of the VPS is commenced with the robotic arm in the predetermined trajectory.

RESULTS

Ventricle was hit in a single attempt in all the cases. CSF leak stopped in the case with meningocele; headache, and visual acuity improved in both the cases of IIH.

CONCLUSION

Robotic-guidance provides a safe and accurate method of VPS placement even in the presence of slit-like ventricles.

Для цитирования: Doddamani Ramesh S, Meena Rajesh, Sawarkar Dattaraj, Singh Pankaj, Agrawal Deepak, Singh Manmohan, Chandra Poodipedi S. Robot-guided Ventriculoperitoneal Shunt in Slit-like Ventricles.. Neurology India. 2021. DOI: 10.4103/0028-3886.314585.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.