MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00404-019-05050-x

Медицинская библиотека · Archives of gynecology and obstetrics · 2019

Three-dimensional ultrasound in the diagnosis and the classification of congenital uterine anomalies using the ESHRE/ESGE classification: a diagnostic accuracy study.

Kougioumtsidou Anna, Mikos Themistoklis, Grimbizis Grigoris F, Karavida Aikaterini, Theodoridis Theodoros D, Sotiriadis Alexandros, Tarlatzis Basil C, Athanasiadis Apostolos P

СтатьяПеревод в очереди

Аннотация

STUDY

OBJECTIVE

To estimate the diagnostic accuracy of three-dimensional ultrasonography (3D US) compared to hysteroscopy/laparoscopy, in the investigation of uterine congenital anomalies using the ESHRE/ESGE classification of female genital tract congenital anomalies.

DESIGN

Prospective blind, comparative, cohort study.

SETTING

University Tertiary Hospital and affiliated private Hospital.

PATIENTS AND

METHODS

Sixty-two women consecutively referred with a suspected diagnosis of uterine congenital anomalies. The ESHRE/ESGE classification of congenital anomalies of the female genital tract was used for the description of abnormal findings.

INTERVENTIONS: All patients underwent (1) 3D US and (2) hysteroscopy with laparoscopy to establish the final diagnosis.

RESULTS

Concordance between 3D US and hysteroscopy with laparoscopy about the type and the classification of uterine anomaly was verified in 61 cases, including all those with septate uterus, dysmorphic uterus, bicorporeal, hemi-uterus or unicorporeal, and aplastic uterus and one out of two with normal uterus. For the diagnosis of septate uteri, which was the most common anomaly, the sensitivity of 3D US was 100%, the specificity was 92.3%, the PPV was 98% and the NPV was 100%, with kappa index 0.950. For bicorporeal, dysmorphic uterus, hemi-uteri or unicorporeal and aplastic uterus the sensitivity, specificity, PPV and NPV were all 100% with K = 1.00. Overall, 3D US showed perfect diagnostic accuracy (Kappa index = 0.945) in the detection of congenital uterine anomalies.

CONCLUSION

3D US appears to be a very accurate method for the diagnosis of congenital uterine anomalies.

Для цитирования: Kougioumtsidou Anna, Mikos Themistoklis, Grimbizis Grigoris F, Karavida Aikaterini, Theodoridis Theodoros D, Sotiriadis Alexandros, Tarlatzis Basil C, Athanasiadis Apostolos P. Three-dimensional ultrasound in the diagnosis and the classification of congenital uterine anomalies using the ESHRE/ESGE classification: a diagnostic accuracy study.. Archives of gynecology and obstetrics. 2019. DOI: 10.1007/s00404-019-05050-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.