DOI 10.1038/s41433-026-04462-9

Медицинская библиотека · Eye (London, England) · 2026

Agreements between 24-2 and 24-2 C test grids for chloroquine/hydroxychloroquine retinopathy patients and high-risk patients.

Wongwachira Chananchida, Suwajanakorn Disorn, Kongwattananon Wijak, Chansangpetch Sunee, Manassakorn Anita, Pongsachareonnont Pear Ferreira, Itthipanichpong Rath, Tantisevi Visanee, Rojanapongpun Prin, Ratanawongphaibul Kitiya

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

PURPOSE: To compare the SITA Standard 24-2 and SITA Faster 24-2 C tests in patients with chloroquine/hydroxychloroquine (CQ/HCQ) retinopathy and those at high risk.

METHODS

A prospective, cross-sectional study of 75 participants who underwent CQ/HCQ retinopathy screening using the SITA Standard 24-2, SITA Faster 24-2 C, optical coherence tomography, fundus autofluorescence, and a dilated eye examination on the same day. Participants were categorized into retinopathy and non-retinopathy groups by graders. The agreement between the two visual field (VF) tests was assessed using Bland-Altman plots.

RESULTS

Among the 75 participants, 10 (13.3%) were diagnosed with CQ/HCQ retinopathy. Bland-Altman plots show good agreement in median deviation (MD), pattern standard deviation (PSD), and central mean sensitivity (CMS) between tests. The concordance coefficient was 0.89-0.93. Significant differences in MD, PSD, and CMS were observed between the retinopathy and non-retinopathy groups for both VF tests (P ≤ 0.02). However, within each group, the results of both VF tests were comparable across all parameters (P = 0.12-0.79), except for PSD in the non-retinopathy group. The SITA Faster 24-2 C test had a significantly shorter testing duration.

CONCLUSIONS

The SITA Standard 24-2 and SITA Faster 24-2 C tests showed similar efficacy and strongly positive agreement in screening for CQ/HCQ retinopathy. However, the SITA Faster 24-2 C minimized the testing time. The addition of testing points within the central 10-degree field did not enhance the detection of CQ/HCQ retinopathy in the Thai population.

Для цитирования: Wongwachira Chananchida, Suwajanakorn Disorn, Kongwattananon Wijak, Chansangpetch Sunee, Manassakorn Anita, Pongsachareonnont Pear Ferreira, Itthipanichpong Rath, Tantisevi Visanee, Rojanapongpun Prin, Ratanawongphaibul Kitiya. Agreements between 24-2 and 24-2 C test grids for chloroquine/hydroxychloroquine retinopathy patients and high-risk patients.. Eye (London, England). 2026. DOI: 10.1038/s41433-026-04462-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.