MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clinbiomech.2004.05.011

Медицинская библиотека · Clinical biomechanics (Bristol, Avon) · 2004

Lateral ankle sprain: isokinetic test reliability and comparison between invertors and evertors.

Amaral De Noronha Marcos, Borges Noé Gomes

Клиническое исследованиеСравнительное исследованиеКонтролируемое клиническое исследованиеСтатьяВалидационное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

Evaluate reliability of isokinetic tests for inversion and eversion in individuals with recurrent lateral ankle sprain and compare inversion to eversion muscle performance in the same ankles.

DESIGN

Reliability was evaluated by comparing the results of two ankle inversion/eversion isokinetic tests. Inversion and eversion were compared with the results presented by the tests.

BACKGROUND

Previous studies showed reliable isokinetic tests for ankles with no sprain history. It is unknown if such tests can also be performed in lateral sprained ankles. It is unclear whether there is difference between invertors and evertors in these ankles.

METHODS

Eleven men with recurrent ankle lateral sprain in one limb were tested using an isokinetic dynamometer. The tests consisted of 5 cycles of maximal contraction in 30 degrees /s and 120 degrees /s. Both injured and noninjured ankles were tested. Peak torque was recorded for analysis.

RESULTS

The tests are reliable and intraclass coefficient correlation varied from 0.71 to 0.95. Invertors generated higher peak torques than evertors (P = 0.03) when injured ankles were tested at 120 degrees /s.

CONCLUSIONS

Isokinetic inversion/eversion tests showed to be reliable. A decrease in peak torques can be seen during higher velocity tests. The only difference between invertors and evertors was seen when injured ankles were tested at 120 degrees /s. In this case invertors showed higher peak torques.

Для цитирования: Amaral De Noronha Marcos, Borges Noé Gomes. Lateral ankle sprain: isokinetic test reliability and comparison between invertors and evertors.. Clinical biomechanics (Bristol, Avon). 2004. DOI: 10.1016/j.clinbiomech.2004.05.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.