MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1259/bjr.20150265

Медицинская библиотека · The British journal of radiology · 2015

Triaxial system in bronchial arterial embolization for haemoptysis using N-butyl-2-cyanoacrylate.

Shimohira Masashi, Hashimoto Takeshi, Abematsu Saori, Hashizume Takuya, Nakagawa Motoo, Ozawa Yoshiyuki, Sakurai Keita, Shibamoto Yuta

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The application of bronchial artery embolization (BAE) using N-butyl-2-cyanoacrylate (NBCA) for haemoptysis was recently reported to be useful. A triple co-axial (triaxial) system consisting of a 4-Fr catheter, 2.7-Fr microcatheter and 1.9-Fr no-taper microcatheter has been developed. The aim of the present study was to evaluate the usefulness of the triaxial system in BAE using NBCA.

METHODS

12 patients with haemoptysis, 8 males and 4 females with a median age of 64 years (range, 49-88 years), underwent BAE between August 2012 and October 2014. Medical records and images were reviewed, and the technical success rate, clinical success rate, haemoptysis-free rate and complications were evaluated. Technical success was defined as the complete cessation of the target artery as confirmed by digital subtraction angiography, whereas clinical success was defined as the cessation of haemoptysis within 24 h of BAE. Recurrent haemoptysis was defined as a total of >30 ml of bleeding per day.

RESULTS

The target artery was embolized successfully in all patients, and the technical success rate was 100% (12/12). The cessation of haemoptysis was achieved in 11 out of 12 patients within 24 h, and thus, the clinical success rate was 92% (11/12). The 6-, 12- and 24-month haemoptysis-free rates were 89%, 89% and 76%, respectively. No patients exhibited any signs of complications such as spinal ischaemia.

CONCLUSION

BAE using the triaxial system and NBCA appears to be a useful and safe procedure for haemoptysis.

ADVANCES IN KNOWLEDGE: The triaxial system contributes to safe and effective BAE using NBCA.

Для цитирования: Shimohira Masashi, Hashimoto Takeshi, Abematsu Saori, Hashizume Takuya, Nakagawa Motoo, Ozawa Yoshiyuki, Sakurai Keita, Shibamoto Yuta. Triaxial system in bronchial arterial embolization for haemoptysis using N-butyl-2-cyanoacrylate.. The British journal of radiology. 2015. DOI: 10.1259/bjr.20150265.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.