MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijmedinf.2023.105192

Медицинская библиотека · International journal of medical informatics · 2023

Development and validation of a prediction model for evaluating extubation readiness in preterm infants.

Song Wongeun, Hwa Jung Young, Cho Jihoon, Baek Hyunyoung, Won Choi Chang, Yoo Sooyoung

Наблюдательное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Successful early extubation has advantages not only in terms of short-term respiratory morbidities and survival but also in terms of long-term neurodevelopmental outcomes in preterm infants. However, no consensus exists regarding the optimal protocol or guidelines for extubation readiness in preterm infants. Therefore, the decision to extubate preterm infants was almost entirely at the attending physician's discretion. We identified robust and quantitative predictors of success or failure of the first planned extubation attempt before 36 weeks of post-menstrual age in preterm infants (<32 weeks gestational age) and developed a prediction model for evaluating extubation readiness using these predictors. Extubation success was defined as the absence of reintubation within 72 h after extubation. This observational cohort study used data from preterm infants admitted to the neonatal intensive care unit of Seoul National University Bundang Hospital in South Korea between July 2003 and June 2019 to identify predictors and develop and test a predictive model for extubation readiness. Data from preterm infants included in the Medical Informative Medicine for Intensive Care (MIMIC-III) database between 2001 and 2008 were used for external validation. From a machine learning model using predictors such as demographics, periodic vital signs, ventilator settings, and respiratory indices, the area under the receiver operating characteristic curve and average precision of our model were 0.805 (95% confidence interval [CI], 0.802-0.809) and 0.917, respectively in the internal validation and 0.715 (95% CI, 0.713-0.717) and 0.838, respectively in the external validation. Our prediction model (NExt-Predictor) demonstrated high performance in assessing extubation readiness in both internal and external validations.

Для цитирования: Song Wongeun, Hwa Jung Young, Cho Jihoon, Baek Hyunyoung, Won Choi Chang, Yoo Sooyoung. Development and validation of a prediction model for evaluating extubation readiness in preterm infants.. International journal of medical informatics. 2023. DOI: 10.1016/j.ijmedinf.2023.105192.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.