MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acsami.0c08457

Медицинская библиотека · ACS applied materials & interfaces · 2020

CNT/Sericin Conductive Nerve Guidance Conduit Promotes Functional Recovery of Transected Peripheral Nerve Injury in a Rat Model.

Li Xiaolin, Yang Wen, Xie Hongjian, Wang Jian, Zhang Lei, Wang Zheng, Wang Lin

СтатьяПеревод в очереди

Аннотация

Peripheral nerve injury usually leads to poor outcomes such as painful neuropathies and disabilities. Autogenous nerve grafting is the current gold standard; however, the limited source of a donor nerve remains a problem. Numerous tissue engineering nerve guidance conduits have been developed as substitutes for autografts. However, a few conduits can achieve the reparative effect equivalent to autografts. Here, we report for the development and application of a carbon nanotube (CNT)/sericin nerve conduit with electrical conductivity and suitable mechanical properties for nerve repair. This CNT/sericin conduit possesses favorable properties including biocompatibility, biodegradability, porous microarchitecture, and suitable swelling property. We thus applied this conduit for bridging a 10 mm gap defect of a transected sciatic nerve combined with electrical stimulation (ES) in a rat injury model. By the end of 12 weeks, we observed that the CNT/sericin conduit combined with electrical stimulation could effectively promote both structural repair and functional recovery comparable to those of the autografts, evidenced by the morphological and histological analyses, electrophysiological responses, functional studies, and target muscle reinnervation evaluations. These findings suggest that this electric conductive CNT/sericin conduit combined with electrical stimulation may have the potential to serve as a new alternative for the repair of transected peripheral nerves.

Для цитирования: Li Xiaolin, Yang Wen, Xie Hongjian, Wang Jian, Zhang Lei, Wang Zheng, Wang Lin. CNT/Sericin Conductive Nerve Guidance Conduit Promotes Functional Recovery of Transected Peripheral Nerve Injury in a Rat Model.. ACS applied materials & interfaces. 2020. DOI: 10.1021/acsami.0c08457.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.