Intra-aortic balloon pump synchronized with chest compressions improves outcome during cardiopulmonary resuscitation in experimental cardiac arrest.

Dogan Emanuel M, Dogan Erika A, Nilsson Kristofer F, Edström Måns

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Intra-aortic balloon pump (IABP) and resuscitative endovascular balloon occlusion of the aorta (REBOA) are two endovascular intervention methods for circulatory support. The aim of this study was to compare the hemodynamic effects of simultaneous mechanical chest compressions (MCC) with IABP, REBOA and those with only MCC (overall and detailed in the MCC cycle) and return of spontaneous circulation (ROSC) during cardiopulmonary resuscitation (CPR) in experimental non-traumatic cardiac arrests (CA).

METHOD: CA was electrically induced (ventricular fibrillation) in 24 anesthetized pigs, which then were randomized to MCC synchronized IABP (n = 8), total occluded REBOA (n = 8), or control (n = 8). After 10 min of CA, CPR with MCC was started followed by one of the interventions after one minute of CPR. Every other minute after MCC start, the pigs were defibrillated with 200 J if VF/ventricular tachycardia, and after six minutes, adrenaline was administered and repeated every four minutes. The proportions of ROSC were calculated. Hemodynamic variables, including systemic blood and coronary perfusion pressures (CPP), and carotid and iliac blood flows, were collected and analyzed with 0.02 s resolution.

RESULTS

In both the IABP and REBOA groups, 7 of 8 animals (87.5 %) achieved ROSC, in contrast with 2 of 8 (25 %) in the control group (P = 0.04). IABP and REBOA significantly increased systemic arterial pressure (P = 0.002 and P = 0.015, respectively), and REBOA also increased CPP and carotid blood flow when compared to controls (P = 0.007 and P = 0.03, respectively). Animals with IABP had a preserved blood flow in the iliac artery during CPR. No differences were detected after ROSC in hemodynamic, metabolic, and organ injury variables between the REBOA and IABP groups.

CONCLUSION

Both IABP and REBOA increased the proportion of ROSC compared to controls. However, REBOA occluded distal blood flow, while IABP maintained it. This study suggests that MCC synchronized IABP could be an adjunct in the treatment of non-traumatic CA.

Для цитирования: Dogan Emanuel M, Dogan Erika A, Nilsson Kristofer F, Edström Måns. Intra-aortic balloon pump synchronized with chest compressions improves outcome during cardiopulmonary resuscitation in experimental cardiac arrest.. Resuscitation. 2024. DOI: 10.1016/j.resuscitation.2024.110433.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.