Abbott ARCHITECT Syphilis TP Chemiluminescent Immunoassay Accurately Diagnoses Past or Current Syphilis in Pregnancy.
Аннотация
OBJECTIVE
We evaluate diagnostic accuracy of the ARCHITECT chemiluminescent immunoassay (CIA) screening test in pregnancy, and evaluate pregnancy outcomes among screen-positive women.
STUDY
DESIGN
Samples from routine prenatal rapid plasma reagin (RPR) tests were collected between June 22 and August 18, 2017 and frozen. Samples were batch-tested with the Abbott ARCHITECT syphilis TP immunoassay (CIA, index test). We calculated sensitivity, specificity, predictive value, and false positivity. We compared pregnancy and neonatal outcomes among screen-positive women.
RESULTS
Of 1,602 specimens, 35 (2.2%) were RPR + ; of those, 24 (69%) were CIA +/Treponema pallidum particle agglutination assay (TPPA)+ and 11 (31%) were CIA-/TPPA-. Of 1,567 RPR- specimens, 14 (0.9%) were CIA + ; of those, 13 (93%) were TPPA + , and one (7%) had a false positive CIA test. Sensitivity of the CIA (95% CI) was 100% (90.5-100%), specificity 99.9% (99.6-100%), positive predictive value 97.4% (86.2-99.9%), and false positive rate 0.06% (0.002-0.4%) for current or past syphilis. Among 37 CIA +/TPPA+ women, seven (19%) had RPR-negative status (Group 1), 11 (30%) had previously treated syphilis (Group 2), and 19 (51%) had active infection (Group 3). One stillbirth occurred in a woman with early, active syphilis identified at delivery; no adverse perinatal outcomes occurred among women in Groups 1 or 2.
CONCLUSION
The ARCHITECT syphilis TP immunoassay accurately diagnoses current or past syphilis in pregnancy. Clinical history and staging remain essential using a reverse algorithm.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.