DOI 10.1016/j.eururo.2009.05.031
Plasma vaporisation of the prostate: initial clinical results.
Аннотация
BACKGROUND
Laser vaporisation of the prostate has had a considerable impact in recent years. In an attempt to achieve tissue vaporisation with bipolar high-frequency generators, plasma vaporisation was recently introduced.
OBJECTIVE
To provide the first clinical information on bipolar plasma vaporisation of the prostate for patients with lower urinary tract symptoms (LUTS) due to bladder outlet obstruction (BOO).
DESIGN, SETTING, AND
PARTICIPANTS
Thirty patients were included in this prospective bicentre study.
INTERVENTION: All patients underwent bipolar plasma vaporisation with a novel electrode (Olympus Winter & Ibe GmbH, Hamburg, Germany).
MEASUREMENTS: International Prostate Symptom Score (IPSS), bother score, maximum flow rate (Q(max)), and postvoid residual were evaluated at baseline and at the time of discharge as well as at 1, 3, and 6 mo after the intervention.
RESULTS AND LIMITATIONS: Mean preoperative prostate volume was 59±32 ml (range: 30-170), and mean operating time was 61±26 min (range: 20-140). Besides one reoperation (conventional transurethral prostatectomy) due to persistent obstruction, no major complication occurred intra- or postoperatively and no blood transfusion was required. Catheterisation time averaged 41±35 h (range: 18-192). Transient mild to moderate dysuria was noted in four patients (13%). At 1, 3, and 6 mo, Q(max) increased from 6.6±2.7 ml/s preoperative to 17.3±4.7 ml/s (p<0.01), 18.5±4.6 ml/s (p<0.01), and 18.1±5.0 ml/s (p<0.01), respectively. The IPSS decreased from 20.8±3.6 to 10.4±3.5 (p<0.01), 8.2±2.9 (p<0.01), and 8.1±3.1 (p<0.01), respectively. These data represent a small nonrandomised study cohort with limited follow-up.
CONCLUSIONS
Our initial experience indicates that bipolar plasma vaporisation might be a safe and effective treatment option for patients with LUTS due to BOO. To define the potential role of this novel technique, randomised trials with longer follow-up are mandatory.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.