MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.mex.2026.103968

Медицинская библиотека · MethodsX · 2026

Microbiological contamination in home continuous positive airway pressure (CPAP) devices. Study protocol.

López-García Verónica, Peña-Otero David, Megías-Lobón Gregoria, Rodríguez-Pascual Luis Carlos, García-Ruíz Natalia, Álvarez-Paredes Ledicia, Gómez-Torres Piedad, Glarreta-Aperte Sergio

СтатьяПеревод в очереди

Аннотация

Home mechanical ventilation is crucial for treating conditions such as obstructive sleep apnea, and its use has increased exponentially. A possible link exists between poor equipment hygiene and the risk of respiratory infections, due to healthcare-related practices; however, the exact effect is unknown. The aim of this study is to determine the level of bacterial and fungal contamination in home continuous positive airway pressure (CPAP) devices. This prospective, cross-sectional study will be conducted at the Burgos University Hospital Complex (CAUBU), Spain. Twenty-five patients undergoing home CPAP treatment for at least six months will be recruited. Microbiological samples will be taken from each patient at critical points of the CPAP device: CPAP housing, tubing, internal filter, interface, and humidifier. Analyses will be performed at the CAUBU Microbiology Department, which is certified under UNE-EN ISO 9001:2015. In addition to microbiological analysis, clinical variables and determinants of patient health will be collected to study potential factors associated with contamination. It is known that 30% of healthcare-associated infections are preventable, so this study aims to improve prevention strategies, health education, and nursing care to reduce the risk of pathogenic contamination related to home respiratory therapy.

Для цитирования: López-García Verónica, Peña-Otero David, Megías-Lobón Gregoria, Rodríguez-Pascual Luis Carlos, García-Ruíz Natalia, Álvarez-Paredes Ledicia, Gómez-Torres Piedad, Glarreta-Aperte Sergio. Microbiological contamination in home continuous positive airway pressure (CPAP) devices. Study protocol.. MethodsX. 2026. DOI: 10.1016/j.mex.2026.103968.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.