MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00423-026-04074-7

Медицинская библиотека · Langenbeck's archives of surgery · 2026

High interobserver reliability of neutrophil phenotyping based on visual determination of CD16/CD62L expression patterns.

Hübner Christian Thomas, de Fraiture Emma, van Eerten Frederique, Klingebiel Felix Karl-Ludwig, Piaz Nathalie, Pape Hans-Christoph, Koenderman Leo, Teuben Michel Paul Johan, Hietbrink Falco

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Analysis of neutrophil surface expression markers offers relevant insights into the inflammatory response following trauma. Recently a neutrophil phenotype classification based on CD16 and CD62L expression has been established. A seven-category visual classification system based on pattern recognition has been introduced for bedside use, but interobserver reliability has not been assessed to date.

METHODS

In this study, 40 participants with varying medical backgrounds were asked to classify 50 CD16/CD62L dot plots using the seven-category scoring system. Participants received a standardized instruction manual for pattern recognition and category classification. Classification accuracy was compared to a predefined gold standard, and interobserver agreement was assessed using Fleiss' Kappa. Additionally, categories were grouped into "low" (0-3) and "high" (4-6) inflammatory states to evaluate clinical applicability.

RESULTS

Agreement across the seven-category scale was moderate overall (κ = 0.473), with higher consistency observed in more extreme phenotypes. Categories 0, 1, and 3 were most frequently confused, whereas plots obtained during severe inflammation (4, 5, 6) were rarely misclassified as non-inflammatory. When grouped into binary low versus high inflammatory states, agreement improved to almost perfect (κ = 0.836).

DISCUSSION: Binary classification of neutrophil phenotypes, and thus identification of severe inflammation after trauma, is reliable across different observer levels and appears well suited for clinical application. The full seven-category scoring system offers greater resolution but shows higher interobserver variability. These findings support the use of simplified immune phenotyping at the bedside, while preserving the full classification system for research settings.

Для цитирования: Hübner Christian Thomas, de Fraiture Emma, van Eerten Frederique, Klingebiel Felix Karl-Ludwig, Piaz Nathalie, Pape Hans-Christoph, Koenderman Leo, Teuben Michel Paul Johan, Hietbrink Falco. High interobserver reliability of neutrophil phenotyping based on visual determination of CD16/CD62L expression patterns.. Langenbeck's archives of surgery. 2026. DOI: 10.1007/s00423-026-04074-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.