Electrical defibrillation outcome prediction by waveform analysis of ventricular fibrillation in cardiac arrest out of hospital patients.

Nakagawa Yoshihide, Sato Yoji, Kojima Takeshi, Wakabayashi Tsutomu, Morita Seiji, Amino Mari, Inokuchi Sadaki

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Indexes such as amplitude spectrum area (AMSA) and power spectrum area (PSA) obtained from electrocardiogram waveform analysis are possible predictors of outcome after electrical defibrillation for ventricular fibrillation (VF). In this study, we examined AMSA and PSA to determine whether these parameters can predict defibrillation outcome.

MATERIALS AND

METHODS

A total of 83 out-of-hospital VF victims were classified into four groups according to type of cardiac rhythm after shock: return of spontaneous circulation (ROSC), VF, pulseless electrical activity (PEA), and asystole. AMSA and PSA were calculated from electrocardiograms prior to shock and compared between groups.

RESULTS

The mean AMSA (4.0-48 Hz) in the ROSC group was 24.2 ± 8.5 mV-Hz, which was significantly higher than that in the VF and asystole groups.

CONCLUSION

It is possible by analyzing the AMSA of VF to predict cases where electrical defibrillation is more likely to return cardiac rhythm. Furthermore, unnecessary electrical shocks with a low possibility of ROSC can be avoided, and chest compression should be continued to prevent myocardial damage and consequently improve prognosis.

Для цитирования: Nakagawa Yoshihide, Sato Yoji, Kojima Takeshi, Wakabayashi Tsutomu, Morita Seiji, Amino Mari, Inokuchi Sadaki. Electrical defibrillation outcome prediction by waveform analysis of ventricular fibrillation in cardiac arrest out of hospital patients.. The Tokai journal of experimental and clinical medicine. 2012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.