MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1148/radiology.220.1.r01jl15231

Медицинская библиотека · Radiology · 2001

Scaphoid fractures: evaluation with high-spatial-resolution US initial results.

Herneth A M, Siegmeth A, Bader T R, Ba-Ssalamah A, Lechner G, Metz V M, Grabenwoeger F

Клиническое исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the diagnostic accuracy of high-spatial-resolution ultrasonography (US) in the diagnosis of scaphoid fractures.

MATERIALS AND

METHODS

In 72 hours after acute wrist trauma, 15 consecutive patients were examined for possible scaphoid fractures clinically and with conventional radiographs, including scaphoid views. Thereafter, high-spatial-resolution US was performed by two experienced radiologists blinded to the results of the previously performed investigations. High-spatial-resolution US of the scaphoid bones was performed from the palmar, lateral, and dorsal directions in the longitudinal and transverse planes. US findings indicative of a scaphoid fracture were cortical discontinuity and/or periosteal elevation. Finally, magnetic resonance (MR) images (short inversion time inversion-recovery, T1- and T2*-weighted) (ie, the standard) of the affected wrist were obtained and evaluated for a possible scaphoid fracture by two radiologists in consensus.

RESULTS

Nine of 15 patients had scaphoid fractures. Seven (78%) of nine patients had positive findings at high-spatial-resolution US and five (56%) had such findings at conventional radiography (ie, four occult scaphoid fractures), with an accuracy of 87% and 73%, respectively. Two (50%) of four radiographically occult scaphoid fractures were depicted with high-spatial-resolution US. Sonographic findings of scaphoid fractures were either cortical discontinuity (n = 4), periosteal elevation (n = 2), or a combination of these two findings (n = 1).

CONCLUSION

High-spatial-resolution US is a reliable diagnostic tool for the evaluation of occult scaphoid fractures and should be considered an adequate alternative diagnostic tool prior to computed tomography or MR imaging.

Для цитирования: Herneth A M, Siegmeth A, Bader T R, Ba-Ssalamah A, Lechner G, Metz V M, Grabenwoeger F. Scaphoid fractures: evaluation with high-spatial-resolution US initial results.. Radiology. 2001. DOI: 10.1148/radiology.220.1.r01jl15231.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.