DOI 10.1016/j.bios.2025.117294

Медицинская библиотека · Biosensors & bioelectronics · 2025

Real-time cardiomyocyte contraction sensing via a neo-flexible magnetic sensor.

Quan Yue, Ding Sen, Wang Yuxin, Chen Xiuping, Zhou Bingpu, Zhou Yinning

СтатьяПеревод в очереди

Аннотация

Assessing heart disease and evaluating drug-induced cardiotoxicity require a deep understanding of the contractile properties of cardiac tissue, particularly at the level of individual cardiomyocytes. Traditional methods for measuring cardiomyocyte contractility present several challenges, including limitations in real-time detection, complex and costly sensing platforms, and biocompatibility issues. To address these challenges, we introduce an innovative magnetic sensor that utilizes a flexible coil cantilever, pioneering the application of electromagnetic induction for detecting cardiomyocyte contractility. This marks the first time such technology has been deployed in typical laboratory settings with straightforward configurations. When cardiomyocytes are cultured on these coils and subjected to a static magnetic field, their contractions induce oscillations in the coils, generating an electromotive force that converts mechanical pulsations into electrical signals. This advanced platform enables long-term, real-time monitoring of cardiac functional characteristics, including contractility, beating rate, and rhythm. It also enables the quantitative assessment of cardiovascular dynamics, such as in response to drugs like isoproterenol and verapamil. Offering a uniquely simple, stable, and efficient method for evaluating drug-induced cardiotoxicity, this novel detection platform underscores the transformative potential of flexible magnetic sensors in real-time cellular detection applications.

Для цитирования: Quan Yue, Ding Sen, Wang Yuxin, Chen Xiuping, Zhou Bingpu, Zhou Yinning. Real-time cardiomyocyte contraction sensing via a neo-flexible magnetic sensor.. Biosensors & bioelectronics. 2025. DOI: 10.1016/j.bios.2025.117294.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.