MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10029-004-0268-8

Медицинская библиотека · Hernia : the journal of hernias and abdominal wall surgery · 2004

Polypropylene in the intra-abdominal position: influence of pore size and surface area.

Conze J, Rosch R, Klinge U, Weiss C, Anurov M, Titkowa S, Oettinger A, Schumpelick V

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Polypropylene is a material widely used in surgery. Because of its association with formation of enterocutaneous fistulae and adhesions, direct contact between mesh and intestine is avoided. The following study was designed to investigate the adhesive potential of different polypropylene meshes when placed in direct contact with intestine.

MATERIAL AND

METHODS

In an established experimental model, a total of 45 chinchilla rabbits underwent laparoscopic placement of meshes with different pore size (Group I: monofilament PP 0.6 mm, Group II: monofilament PP 2.5 mm, Group III: multifilament PP 4.0 mm) with the Intra-Peritoneal-Onlay-Mesh Technique (IPOM). The degree of adhesion formation was measured after 7, 21, and 90 days, evaluated by an adhesion score, quantified by computer-assisted planimetry, followed by histological and morphometric investigation of the perifilamental granuloma formation.

RESULTS

The heavyweight, small porous polypropylene meshes (PP 0.6) showed significantly stronger adhesion formation at all intervals of investigation compared with the lightweight meshes with a pore size >2.5 mm. Between the two different lightweight mesh variations, there was no significant difference. Granuloma formation was lowest in large-pore-size monofilament meshes (PP 2.5).

CONCLUSION

The IPOM rabbit model is suitable for investigation of biomaterials in the intra-abdominal position. Our results show that the adhesive potential is significantly influenced by the pore size. However, the extent of the foreign-body reaction seems also to be influenced by the filament structure, respectively, the surface area, favoring monofilament material.

Для цитирования: Conze J, Rosch R, Klinge U, Weiss C, Anurov M, Titkowa S, Oettinger A, Schumpelick V. Polypropylene in the intra-abdominal position: influence of pore size and surface area.. Hernia : the journal of hernias and abdominal wall surgery. 2004. DOI: 10.1007/s10029-004-0268-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.