BACKGROUND

Renal denervation (RDN) can lower blood pressure (BP) in patients with hypertension in both the presence and absence of medication. This is a sham-controlled trial investigating the safety and efficacy of RDN in China.

METHODS

This prospective, multicenter, randomized, patient- and outcome-assessor-blinded, sham-controlled trial investigated radiofrequency RDN in patients with hypertension on standardized triple antihypertensive therapy. Eligible patients were randomized 1:1 to undergo RDN using a multi-electrode radiofrequency catheter (Iberis; Shanghai Angiocare Medical Technology, Shanghai, China) or a sham procedure. The primary efficacy outcome was the between-group difference in baseline-adjusted change in mean 24-hour ambulatory systolic BP from randomization to 6 months.

RESULTS

Of 217 randomized patients (mean age, 45.3±10.2 years; 21% female), 107 were randomized to RDN and 110 were randomized to sham control. At 6 months, there was a greater reduction in 24-hour systolic BP in the RDN (-13.0±12.1 mm Hg) compared with the sham control group (-3.0±13.0 mm Hg; baseline-adjusted between-group difference, -9.4 mm Hg [95% CI, -12.8 to -5.9]; P<0.001). Compared with sham, 24-hour diastolic BP was lowered by -5.0 mm Hg ([95% CI, -7.5 to -2.4]; P<0.001) 6 months after RDN, and office systolic and diastolic BP was lowered by -6.4 mm Hg ([95% CI, -10.5 to -2.3]; P=0.003) and -5.1 mm Hg ([95% CI, -8.2 to -2.0]; P=0.001), respectively. One patient in the RDN group experienced an access site complication (hematoma), which resolved without sequelae. No other major device- or procedure-related safety events occurred through follow-up.

CONCLUSIONS

In this trial of Chinese patients with uncontrolled hypertension on a standardized triple pharmacotherapy, RDN was safe and reduced ambulatory and office BP at 6 months compared with sham.

REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02901704.

Для цитирования: Jiang Xiongjing, Mahfoud Felix, Li Wei, Dong Hui, Yu Jing, Yu Shuhua, Chen Xiaoping, Wang Peijian, Li Zhiqiang, Lauder Lucas, Wang Zhifang, Ji Zheng, Dong Yifei, Han Bing, Zhu Zhiming, Chen Yulin, Xu Jianzhong, Zhao Xingsheng, Fan Weidong, Xie Wen, Hubbard Brad, Hu Xi, Kario Kazuomi, Gao Runlin. Efficacy and Safety of Catheter-Based Radiofrequency Renal Denervation in Chinese Patients With Uncontrolled Hypertension: The Randomized, Sham-Controlled, Multi-Center Iberis-HTN Trial.. Circulation. 2024. DOI: 10.1161/circulationaha.124.069215.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.