Transport and Anaesthesia Consideration for Transcatheter Patent Ductus Arteriosus Closure in Premature Infants.
Аннотация
Transcatheter device closure of patent ductus arteriosus (PDA) in preterm infants has been proven to be a feasible and safe technique with promising results when compared to surgical ligation. However, managing transport and anaesthesia in extremely premature infants with haemodynamically significant PDA and limited reserves presents unique challenges. This review article focuses on the key considerations throughout the clinical pathway for the PDA device closure, including referral hospital consultation, patient selection, intra- and inter-hospital transport, and anaesthesia management. The key elements encompass comprehensive patient assessment, meticulous airway management, optimised ventilation strategies, precise thermoregulation, patient-tailored sedation protocols, vigilant haemodynamic monitoring, and safe transport measures throughout the pre-operative, intra-operative, and post-operative phases. A multidisciplinary approach enhances the chances of procedure success, improves patient outcomes, and minimises the risk of complications.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.