MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jpedsurg.2012.08.019

Медицинская библиотека · Journal of pediatric surgery · 2013

Preliminary investigation of the diagnosis of neonatal congenital esophageal atresia using high-resolution ultrasonography: a report of three cases.

Li Shixing, Su Pengjun, Feng Shu, Ju Hao, Shi Bo, Huang Ying, Zhang Zhibo

Клинический случайСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To investigate the clinical value of high-resolution ultrasonography (US) in the diagnosis of neonatal congenital esophageal atresia.

MATERIALS AND

METHODS

Longitudinal or oblique mediastinal and abdominal scans were performed using a high-frequency, linear array Philip IU22 probe of 5-13MHz to measure the length and diameter of the upper and lower esophageal pouches, as well as the gap length.

RESULTS

Three neonates with esophageal atresia received surgical treatment. For each case, the length and diameter of the blind upper and/or lower esophageal pouches were measured by ultrasonography. The gaps in two of three cases were long (>3cm), and in one case, it was short (<2cm).

CONCLUSIONS

High-resolution ultrasonography can demonstrate clearly the upper and lower pouches, as well as wall features, and has a clear advantage in measuring the length of the lower esophageal pouch and the gap, which is impossible with plain radiography and esophagography. The drawback is that ultrasonography failed to clearly demonstrate the fistula between the esophagus and the trachea. Despite this, high-resolution ultrasonography is a promising modality in the clinical diagnosis of esophageal atresia.

Для цитирования: Li Shixing, Su Pengjun, Feng Shu, Ju Hao, Shi Bo, Huang Ying, Zhang Zhibo. Preliminary investigation of the diagnosis of neonatal congenital esophageal atresia using high-resolution ultrasonography: a report of three cases.. Journal of pediatric surgery. 2013. DOI: 10.1016/j.jpedsurg.2012.08.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.