MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10396-020-01071-1

Медицинская библиотека · Journal of medical ultrasonics (2001) · 2021

Reliability of an ultrasonographical scoring system for diagnosis of sinusoidal obstruction syndrome/veno-occlusive disease in patients with hematopoietic stem cell transplantation.

Iwai Takahito, Nishida Mutsumi, Sugita Junichi, Kudo Yusuke, Takasugi Rika, Yokota Isao, Takagi Ryo, Shibuya Hitoshi, Takahashi Shuichiro, Teshima Takanori

СтатьяПеревод в очереди

Аннотация

PURPOSE: Sinusoidal obstruction syndrome (SOS)/hepatic veno-occlusive disease (VOD) is a fatal complication after hematopoietic stem cell transplantation. We previously reported the usefulness of an ultrasonographical (US) scoring system, the Hokkaido US-based scoring system consisting of ten parameters (HokUS-10): (1) hepatomegaly in the left lobe and (2) right lobe, (3) dilatation of the main portal vein (PV), (4) hepatofugal flow in the main PV, (5) decreased velocity of the PV, (6) dilatation of the para-umbilical vein (PUV), (7) appearance of blood flow signal in the PUV, (8) gallbladder (GB) wall thickening, (9) ascites, and (10) increased resistive index of the hepatic artery, for the diagnosis of SOS/VOD. However, the reliability of this system among operators remains elusive. Therefore, we prospectively evaluated the reliability of HokUS-10.

METHODS

Twenty-four healthy volunteers and 40 patients with liver dysfunction were enrolled. Inter- and intra-operator reliabilities were analyzed using three sonographers.

RESULTS

The median concordance rate of HokUS-10 among three sonographers and intra-operator in 24 volunteers was 92% (95% CI: 73-98%) and 98% (95% CI: 92-100%), respectively. In all 64 cases, in terms of the reliability between two sonographers for three representative US parameters (amount of ascites, GB wall thickening, and appearance of PUV blood flow signal), the median concordance rate was more than 98% (95% CI: 86-106%).

CONCLUSION

The inter- and intra-reliabilities of HokUS-10 were excellent. Thus, US might be a reliable tool for SOS/VOD diagnosis.

Для цитирования: Iwai Takahito, Nishida Mutsumi, Sugita Junichi, Kudo Yusuke, Takasugi Rika, Yokota Isao, Takagi Ryo, Shibuya Hitoshi, Takahashi Shuichiro, Teshima Takanori. Reliability of an ultrasonographical scoring system for diagnosis of sinusoidal obstruction syndrome/veno-occlusive disease in patients with hematopoietic stem cell transplantation.. Journal of medical ultrasonics (2001). 2021. DOI: 10.1007/s10396-020-01071-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.