MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acs.analchem.4c05482

Медицинская библиотека · Analytical chemistry · 2024

An Entropy-Driven Multipedal DNA Walker Microsensor for In Situ Electrochemical Detection of ATP.

Jiang Hong, Liu Xiao, Zhao Dong, Jia Yu-Kang, Wang Ya-Qin, Li Wei, Liu Zhao-Peng, Wang Ji-Dong

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Microelectrode- and nanoelectrode-based electrochemistry has become a powerful tool for the in situ monitoring of various biomolecules in vivo. However, two challenges limit the application of micro- and nanoelectrodes: the difficulty of highly sensitive detection of nonelectroactive molecules and the specific detection of target molecules in complex biological environments. Herein, we propose an electrochemical microsensor based on an entropy-driven multipedal DNA walker for the highly sensitive and selective detection of ATP. An ATP aptamer was immobilized on the microelectrode surface to form the DNA walker track for selective ATP recognition. Multiple walking "legs" were attached to quantum dots to create the multipedal DNA walker. ATP was selectively captured by the ATP aptamer, triggering the autonomous movement of the multipedal DNA walker on the microelectrode interface, which brought methylene blue (MB) closer to the microelectrode interface, realizing a cascade signal amplification. Additionally, ATP release induced by hypotonic conditions in BV2 cells was successfully monitored, indicating that increased cell volume enhances ATP release. This multipedal DNA walker microsensor offers a novel strategy for in situ, highly sensitive, and selective monitoring of nonelectroactive biomolecules in vivo, which is crucial for investigating the neurochemical processes involved in neurological diseases.

Для цитирования: Jiang Hong, Liu Xiao, Zhao Dong, Jia Yu-Kang, Wang Ya-Qin, Li Wei, Liu Zhao-Peng, Wang Ji-Dong. An Entropy-Driven Multipedal DNA Walker Microsensor for In Situ Electrochemical Detection of ATP.. Analytical chemistry. 2024. DOI: 10.1021/acs.analchem.4c05482.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.