MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1302/0301-620x.89b11.19018

Медицинская библиотека · The Journal of bone and joint surgery. British volume · 2007

Anatomical study of the placement of proximal oblique locking screws in intramedullary tibial nailing.

Jones B G, Mehin R, Young D

СтатьяПеревод в очереди

Аннотация

Intramedullary tibial nailing was performed in ten paired cadavers and the insertion of a medial-to-lateral proximal oblique locking screw was simulated in each specimen. Anatomical dissection was undertaken to determine the relationship of the common peroneal nerve to the cross-screw. The common peroneal nerve was contacted directly in four tibiae and the cross-screw was a mean of 2.6 mm (1.0 to 10.7) away from the nerve in the remaining 16. Iatrogenic injury to the common peroneal nerve by medial-to-lateral proximal oblique locking screws is therefore a significant risk during tibial nailing.

Для цитирования: Jones B G, Mehin R, Young D. Anatomical study of the placement of proximal oblique locking screws in intramedullary tibial nailing.. The Journal of bone and joint surgery. British volume. 2007. DOI: 10.1302/0301-620x.89b11.19018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.