MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3802/jgo.2018.29.e52

Медицинская библиотека · Journal of gynecologic oncology · 2018

Quality of tissue from punch biopsy forceps vs. round loop electrode in colposcopically directed biopsy: a randomized controlled trial.

Lee Sung Won, Kwak Dong Shin, Jung In Sub, Kwak Joo Hee, Park Jung Hwan, Hong Sang Mo, Lee Chang Bum, Park Yong Soo, Kim Dong Sun, Choi Woong Hwan, Ahn You Hern

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

To compare the quality of tissue from punch biopsy forceps (PB group) with round loop electrode (LE group) in colposcopically directed biopsy along with the evaluation of pain associated with each procedure.

METHODS

Patients with abnormal cervical cytologic results and abnormal colposcopic findings were enrolled into a randomized trial into either a PB group or LE group. The quality of tissue was evaluated in regards to the size of tissue, site of tissue, and tissue damage. Each quality had 1 to 3 points and the sum of each quality contributed to the total tissue score that ranged from 3 to 9. Pain associated with each procedure was assessed by a visual analog scale (VAS). This was a clinical trial study and was registered at www.clinicaltrials.in.th (Identifier: TCTR20160404001).

RESULTS

Ninety-six women who met all eligibility requirements were enrolled in the study. Forty-eight patients were randomly assigned to the PB group and 48 patients were randomized into the LE group. The characteristics of the patients were similar between the 2 groups with the exception of the median age. The median total tissue score was 8 points in the LE group which was more than the median of 7 points in the PB group with a statistically significant difference (p=0.014). However, the median VAS pain score in both groups was 3.4 (p=0.82).

CONCLUSION

The quality of cervical tissues obtained from biopsy with a round loop electrode was better than the punch biopsy forceps with no difference in the level of pain.

Для цитирования: Lee Sung Won, Kwak Dong Shin, Jung In Sub, Kwak Joo Hee, Park Jung Hwan, Hong Sang Mo, Lee Chang Bum, Park Yong Soo, Kim Dong Sun, Choi Woong Hwan, Ahn You Hern. Quality of tissue from punch biopsy forceps vs. round loop electrode in colposcopically directed biopsy: a randomized controlled trial.. Journal of gynecologic oncology. 2018. DOI: 10.3802/jgo.2018.29.e52.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.