Sestamibi Single-Positron Emission Computed Tomography/Diagnostic-quality Computed Tomography for the localization of abnormal parathyroid glands in patients with primary hyperparathyroidism: What clinicopathologic factors affect its accuracy?

Yang J, Wang H, Zhang J, Xu W, Weng W, Lv S, Dong M

СтатьяПеревод в очереди

Аннотация

PURPOSE: Sestamibi Single-Positron Emission Computed Tomography/Diagnostic-quality Computed Tomography (MIBI-SPECT/CT) is a common technology used for primary hyperparathyroidism (PHPT) localization in clinical practice. However, the clinicopathologic factors affecting the accuracy of MIBI-SPECT/CT and the potential limitations remain unclear.

METHODS

Retrospectively enrolled PHPT patients (n = 280) were analyzed from August 2017 to December 2019.

RESULTS

Of 96 patients with PHPT (mean age, 54 years; 63 females), 17 had discordance between MIBI-SPECT/CT and intraoperative findings. Among the 17 patients with discordance, 58.8% had major discordance, which occurred in most patients with multigland disease (MGD). Compared with concordant patients, discordant patients exhibited increased frequencies of autoimmune thyroid disease (29.4% vs 10.1%, p = 0.035), MDG (41.2% vs 3.8%, p = 0.035), higher PTH (296 pg/mL vs 146 pg/mL; p = 0.012),and lower phosphorus levels (0.77 mmol/L vs 0.90 mmol/L; p = 0.024). MDG (odds ratio [OR], 16.95; 95% CI 2.10-142.86), parathyroid lesion size of 12 mm or less (OR, 6.93; 95% CI 1.41-34.10), and a PTH level higher than 192.5 pg/mL (OR, 12.66; 95% CI 2.17-71.43) were independently associated with discordant MIBI-SPECT/CT results.

CONCLUSION

MGD was most strongly associated with discordance between MIBI-SPECT/CT and intraoperative findings followed by a PTH level higher than 192.5 pg/mL and parathyroid lesion size of 12 mm or less. Surgeons should recognize these potential limitations, which may improve the preoperative procedure by encouraging further localization imaging and promptly facilitate intraoperative troubleshooting.

Для цитирования: Yang J, Wang H, Zhang J, Xu W, Weng W, Lv S, Dong M. Sestamibi Single-Positron Emission Computed Tomography/Diagnostic-quality Computed Tomography for the localization of abnormal parathyroid glands in patients with primary hyperparathyroidism: What clinicopathologic factors affect its accuracy?. Journal of endocrinological investigation. 2021. DOI: 10.1007/s40618-020-01471-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.