MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jcla.70278

Медицинская библиотека · Journal of clinical laboratory analysis · 2026

Duplex Recombinase Polymerase Amplification-Lateral Flow Assay for Rapid Visual Detection of Critical Antibiotic Resistance Genes in Escherichia coli and Klebsiella pneumoniae From Positive Blood Cultures.

Nemidkanam Variya, Deechart Pattamaporn, Chaichanawongsaroj Nuntaree

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Bloodstream infections (BSIs) caused by multidrug-resistant bacteria (MDR) are a leading cause of mortality and morbidity among hospitalized patients. Extended-Spectrum Beta-Lactamase (ESBL), carbapenem-resistant Enterobacterales (CRE), and colistin resistance are critically important antibiotic-resistant bacteria. The rapid identification of these critical antibiotic resistance genes from positive blood cultures is essential for accelerating the diagnostic turnaround time, enabling early therapy, and supporting effective antibiotic stewardship programs.

METHODS

Recombinase Polymerase Amplification (RPA) integrated with an in-house Lateral Flow Assay (LFA) for duplex detection of blaCTX-M/mcr-1 and blaoxa-48-like/blaNDM was established in this study. 5' modified primers compatible with those immobilized antibodies on LFA were designed. The primer concentrations, temperature, and time were optimized at 0.2-0.6 μM, 36°C-39°C, and 20-30 min, respectively. The duplex RPA amplicons were diluted in buffer and visually detected on in-house lateral flow strips within 10-15 min. The limit of detection (LOD), specificity, and method validation were evaluated.

RESULTS

The optimal primer concentrations of blaCTX-M/mcr-1 (0.35 μM/0.35 μM) and blaoxa-48-like/blaNDM (0.2 μM/0.6 μM) provided balanced signal intensities for all target genes at 37°C-38°C within 25 min. The LOD across incubation time of 0-8 h was determined as 107-102 CFU/mL. No cross-reactivity was observed with other common Gram-negative pathogens. Sensitivity and specificity of duplex RPA-LFA for blaCTX-M, mcr-1, and blaoxa-48-like/blaNDM detection were 85.71%-98.28% and 93.62%-100%. The accuracy was 93.33%-96.13%.

CONCLUSION

This developed duplex RPA-LFA assay is well-suited for rapid screening in positive blood cultures, providing a cost-effective tool for the treatment, surveillance, and control of MDR in critical infections.

Для цитирования: Nemidkanam Variya, Deechart Pattamaporn, Chaichanawongsaroj Nuntaree. Duplex Recombinase Polymerase Amplification-Lateral Flow Assay for Rapid Visual Detection of Critical Antibiotic Resistance Genes in Escherichia coli and Klebsiella pneumoniae From Positive Blood Cultures.. Journal of clinical laboratory analysis. 2026. DOI: 10.1002/jcla.70278.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.